One thing that jumps out at me is using the S3700 for OS but the S3500 for 
journals. I would use the S3700 for journals and S3500 for the OS. Looks pretty 
good other than that! 




From: "German Anders" <[email protected]> 
To: "ceph-users" <[email protected]> 
Sent: Monday, June 29, 2015 12:24:41 PM 
Subject: [ceph-users] infiniband implementation 

hi cephers, 

Want to know if there's any 'best' practice or procedure to implement Ceph with 
Infiniband FDR 56gb/s for front and back end connectivity. Any crush tunning 
parameters, etc. 

The Ceph cluster has: 

- 8 OSD servers 
- 2x Intel Xeon E5 8C with HT 
- 128G RAM 
- 2x 200G Intel DC S3700 (RAID-1) OS 
- 3x 200G Intel DC S3500 - Journals 
- 4x 800G Intel DC S3500 - OSD SSD & Journal on same disks 
- 4x 3TB - OSD SATA 
- 1x IB FDR ADPT DP 

- 3 MON servers 
- 2x Intel Xeon E5 6C with HT 
- 128G RAM 
- 2x 200G Intel SSD (RAID-1) OS 
- 1x IB FDR ADP DP 

All with Ubuntu 14.04.1LTS with Kern 4.0.6 


Thanks in advance, 



German 

_______________________________________________ 
ceph-users mailing list 
[email protected] 
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com 
_______________________________________________
ceph-users mailing list
[email protected]
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com

Reply via email to