Hi all,

I am curious what practices other people follow when removing OSDs from a
cluster. According to the docs, you are supposed to:

1. ceph osd out
2. stop daemon
3. ceph osd crush remove
4. ceph auth del
5. ceph osd rm

What value does ceph osd out (1) add to the removal process and why is it
in the docs ? We have found (as have others) that by outing(1) and then
crush removing (3), the cluster has to do two recoveries. Is it necessary?
Can you just do a crush remove without step 1?

I found this earlier message from GregF which he seems to affirm that just
doing the crush remove is fine:
http://lists.ceph.com/pipermail/ceph-users-ceph.com/2014-January/007227.html

This recent blog post from Sebastien that suggests reweighting to 0 first,
but havent tested it:
http://www.sebastien-han.fr/blog/2015/12/11/ceph-properly-remove-an-osd/

I thought that by marking it out, it sets the reweight to 0 anyway, so not
sure how this would make a difference in terms of two rebalances but maybe
there is a subtle difference.. ?

Thanks,
Raf

-- 
Senior Storage Engineer - Automation and Delivery
Infrastructure Services - eSolutions
_______________________________________________
ceph-users mailing list
[email protected]
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com

Reply via email to