Thanks!

It seems to work!


I configure my cluster's crush rulesest according to 
https://elkano.org/blog/ceph-sata-ssd-pools-server-editing-crushmap/.
Then restart my cluster, things looks like ok.


My tests have not finished.
Go on making tier-cache.


ceph osd tier add images images ssdpool
ceph osd tier cache-mode ssdpool writeback
ceph osd tier add images volumes ssdpool
ceph osd tier cache-mode ssdpool writeback



But 'ceph -s' replys:


1 cache pools are missing hit_sets


And then 'ceph osd tree' replys(a bit longer):


ID  WEIGHT  TYPE NAME                    UP/DOWN REWEIGHT PRIMARY-AFFINITY  -10 
0.59999 root default-ssd                                                 -6 
0.14000     host bjd-01-control1-ssd                                      3 
0.06999         osd.3                   down  1.00000          1.00000    4 
0.06999         osd.4                   down  1.00000          1.00000   -7 
0.14000     host bjd-01-control2-ssd                                     11 
0.06999         osd.11                  down  1.00000          1.00000   12 
0.06999         osd.12                  down  1.00000          1.00000   -8 
0.17999     host bjd-01-compute1-ssd                                     18 
0.09000         osd.18                  down  1.00000          1.00000   19 
0.09000         osd.19                  down  1.00000          1.00000   -9 
0.14000     host bjd-01-compute2-ssd                                     28 
0.06999         osd.28                  down  1.00000          1.00000   29 
0.06999         osd.29                  down  1.00000          1.00000   -1 
6.06000 root default                                                     -2 
1.50000     host bjd-01-control1                                          0 
0.25000         osd.0                     up  1.00000          1.00000    2 
0.25000         osd.2                     up  1.00000          1.00000    5 
0.25000         osd.5                     up  1.00000          1.00000    6 
0.25000         osd.6                     up  1.00000          1.00000   22 
0.25000         osd.22                    up  1.00000          1.00000   23 
0.25000         osd.23                    up  1.00000          1.00000   -3 
1.50000     host bjd-01-control2                                          7 
0.25000         osd.7                     up  1.00000          1.00000    8 
0.25000         osd.8                     up  1.00000          1.00000    9 
0.25000         osd.9                     up  1.00000          1.00000   10 
0.25000         osd.10                    up  1.00000          1.00000   13 
0.25000         osd.13                    up  1.00000          1.00000   14 
0.25000         osd.14                    up  1.00000          1.00000   -4 
1.56000     host bjd-01-compute1                                         15 
0.25000         osd.15                    up  1.00000          1.00000   16 
0.25000         osd.16                    up  1.00000          1.00000   17 
0.26999         osd.17                    up  1.00000          1.00000   20 
0.26999         osd.20                    up  1.00000          1.00000   21 
0.26999         osd.21                    up  1.00000          1.00000    1 
0.25000         osd.1                     up  1.00000          1.00000   -5 
1.50000     host bjd-01-compute2                                         24 
0.25000         osd.24                    up  1.00000          1.00000   25 
0.25000         osd.25                    up  1.00000          1.00000   26 
0.25000         osd.26                    up  1.00000          1.00000   27 
0.25000         osd.27                    up  1.00000          1.00000   30 
0.25000         osd.30                    up  1.00000          1.00000   31 
0.25000         osd.31                    up  1.00000          1.00000
 


In the end, i run ceph-osd manually, 'ceph-osd -i 12 -c /etc/ceph/ceph.conf -f':


SG_IO: bad/missing sense data, sb[]:  70 00 05 00 00 00 00 0d 00 00 00 00 20 00 
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SG_IO: bad/missing sense data, sb[]:  70 00 05 00 00 00 00 0d 00 00 00 00 20 00 
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
2016-06-08 06:21:58.335164 7fc376d74880 -1 osd.12 383 log_to_monitors 
{default=true}
./include/interval_set.h: In function 'void interval_set<T>::erase(T, T) [with 
T = snapid_t]' thread 7fc34dbe9700 time 2016-06-08 06:21:58.341270
./include/interval_set.h: 386: FAILED assert(_size >= 0)
./include/interval_set.h: In function 'void interval_set<T>::erase(T, T) [with 
T = snapid_t]' thread 7fc34d3e8700 time 2016-06-08 06:21:58.341246
./include/interval_set.h: 386: FAILED assert(_size >= 0)
./include/interval_set.h: In function 'void interval_set<T>::erase(T, T) [with 
T = snapid_t]' thread 7fc34c3e6700 time 2016-06-08 06:21:58.342349
./include/interval_set.h: 386: FAILED assert(_size >= 0)
./include/interval_set.h: In function 'void interval_set<T>::erase(T, T) [with 
T = snapid_t]' thread 7fc34abe3700 time 2016-06-08 06:21:58.341558
./include/interval_set.h: 386: FAILED assert(_size >= 0)
./include/interval_set.h: In function 'void interval_set<T>::erase(T, T) [with 
T = snapid_t]' thread 7fc34bbe5700 time 2016-06-08 06:21:58.342344
./include/interval_set.h: 386: FAILED assert(_size >= 0)
 ceph version 0.94.6 (e832001feaf8c176593e0325c8298e3f16dfb403)
 1: (ceph::__ceph_assert_fail(char const*, char const*, int, char const*)+0x85) 
[0xbc9195]
 2: (interval_set<snapid_t>::subtract(interval_set<snapid_t> const&)+0xc0) 
[0x81ec80]
 3: (PGPool::update(std::tr1::shared_ptr<OSDMap const>)+0x54e) [0x7f21be]
 4: (PG::handle_advance_map(std::tr1::shared_ptr<OSDMap const>, 
std::tr1::shared_ptr<OSDMap const>, std::vector<int, std::allocator<int> >&, 
int, std::vector<int, std::allocator<int> >&, int, PG::RecoveryCtx*)+0x2a2) 
[0x7f26f2]
 5: (OSD::advance_pg(unsigned int, PG*, ThreadPool::TPHandle&, 
PG::RecoveryCtx*, std::set<boost::intrusive_ptr<PG>, 
std::less<boost::intrusive_ptr<PG> >, std::allocator<boost::intrusive_ptr<PG> > 
>*)+0x2da) [0x6a591a]
 6: (OSD::process_peering_events(std::list<PG*, std::allocator<PG*> > const&, 
ThreadPool::TPHandle&)+0x22c) [0x6a643c]
 7: (OSD::PeeringWQ::_process(std::list<PG*, std::allocator<PG*> > const&, 
ThreadPool::TPHandle&)+0x28) [0x701d88]
 8: (ThreadPool::worker(ThreadPool::WorkThread*)+0xa76) [0xbb9966]
 9: (ThreadPool::WorkThread::entry()+0x10) [0xbba9f0]
 10: (()+0x7dc5) [0x7fc3756ffdc5]
 11: (clone()+0x6d) [0x7fc3741e228d]
 NOTE: a copy of the executable, or `objdump -rdS <executable>` is needed to 
interpret this.
2016-06-08 06:21:58.355662 7fc34d3e8700 -1 ./include/interval_set.h: In 
function 'void interval_set<T>::erase(T, T) [with T = snapid_t]' thread 
7fc34d3e8700 time 2016-06-08 06:21:58.341246
./include/interval_set.h: 386: FAILED assert(_size >= 0)





Q: can a pool tier to other pools more than once? like my case, 
ssdpool--tier--images & ssdpool--tier--volumes.


Best regards,


Xiucai
------------------ ???????? ------------------
??????: "Christian Balzer";<[email protected]>;
????????: 2016??6??8??(??????) ????11:16
??????: "ceph-users"<[email protected]>; 
????: "????"<[email protected]>; 
????: Re: [ceph-users] Must host bucket name be the same with hostname ?




Hello,

you will want to read:
https://www.sebastien-han.fr/blog/2014/08/25/ceph-mix-sata-and-ssd-within-the-same-box/

especially section III and IV.

Another approach w/o editing the CRUSH map is here:
https://elkano.org/blog/ceph-sata-ssd-pools-server-editing-crushmap/

Christian

On Wed, 8 Jun 2016 10:54:36 +0800 ???? wrote:

> Hi all,
> 
>     There are SASes & SSDs in my nodes at the same time.
>     Now i want divide them into 2 groups, one composed of SASes and one
> only contained SSDs. When i configure CRUSH rulesets, segment below:
> 
> 
>         # buckets
>         host robert-a {
>       id -2           # do not change unnecessarily
>       # weight 1.640
>       alg straw
>       hash 0  # rjenkins1
>       item osd.0 weight 0.250    #SAS
>       item osd.1 weight 0.250    #SAS
>       item osd.2 weight 0.250    #SSD
>       item osd.3 weight 0.250    #SSD
> 
>         }
> 
> 
>     So, i am not sure must host bucket name be the same with hostname.
> 
> 
>     Or host bucket name does no matter?
> 
> 
> 
> Best regards,
> 
> Xiucai

-- 
Christian Balzer        Network/Systems Engineer                
[email protected]           Global OnLine Japan/Rakuten Communications
http://www.gol.com/
_______________________________________________
ceph-users mailing list
[email protected]
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com