Hello cephers

we have many (millions,  small objects in our RadosGW system and are
getting not very good write performance, 100-200 PUTs /sec.

I have read on the mailinglist that one possible tuning option would be to
increase the max. number of files per directory on OSDs with eg.

filestore merge threshold = 40
filestore split multiple = 8

Now my question is, do we need to rebuild the OSDs to make this effective?
Or is it a runtime setting?

I'm asking because when setting this with injectargs I get the message
"unchangeable" back.

Thanks for any insight.
_______________________________________________
ceph-users mailing list
[email protected]
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com

Reply via email to