robocopy in Windows have flag /MT:N, where N - thread's count. With MT:24 I have 20-30MB/sec copy from one VM instance to another. It's all after disabling scrub in working time.
>Вторник, 12 июля 2016, 5:44 +05:00 от Christian Balzer <[email protected]>: > > >Hello, > >scrub settings will only apply to new scrubs, not running ones, as you >found out. > >On Mon, 11 Jul 2016 15:37:49 +0300 K K wrote: > >> >> I have tested windows instance Crystal Disk Mark. Result is: >> >Again, when running a test like this, check with atop/iostat how your >OSDs/HDDs are doing > >> Sequential Read : 43.049 MB/s >> Sequential Write : 45.181 MB/s >> Random Read 512KB : 78.660 MB/s >> Random Write 512KB : 39.292 MB/s >> Random Read 4KB (QD=1) : 3.511 MB/s [ 857.3 IOPS] >> Random Write 4KB (QD=1) : 1.380 MB/s [ 337.0 IOPS] >> Random Read 4KB (QD=32) : 32.220 MB/s [ 7866.1 IOPS] >> Random Write 4KB (QD=32) : 12.564 MB/s [ 3067.4 IOPS] >> Test : 4000 MB [D: 97.5% (15699.7/16103.1 GB)] (x3) >> > >These numbers aren't all that bad, with your network and w/o SSD journals >the 4KB ones are pretty much on par. > >You may get better read performance by permanently enabling read-ahead, as >per: >http://docs.ceph.com/docs/hammer/rbd/rbd-config-ref/ > >Windows may have native settings to do that, but I know zilch about that. > >Christian > >> >Понедельник, 11 июля 2016, 12:38 +05:00 от Christian Balzer < [email protected] >> >>: >> > >> > >> >Hello, >> > >> >On Mon, 11 Jul 2016 09:54:59 +0300 K K wrote: >> > >> >> >> >> > I hope the fastest of these MONs (CPU and storage) has the lowest IP >> >> > number and thus is the leader. >> >> no, the lowest IP has slowest CPU. But zabbix didn't show any load at all >> >> mons. >> > >> >In your use case and configuration no surprise, but again, the lowest IP >> >will be leader by default and thus the busiest. >> > >> >> > Also what Ceph, OS, kernel version? >> >> >> >> ubuntu 16.04 kernel 4.4.0-22 >> >> >> >Check the ML archives, I remember people having performance issues with the >> >4.4 kernels. >> > >> >Still don't know your Ceph version, is it the latest Jewel? >> > >> >> > Two GbE ports, given the "frontend" up there with the MON description I >> >> > assume that's 1 port per client (front) and cluster (back) network? >> >> yes, one GbE for ceph client, one GbE for back network. >> >OK, so (from a single GbE client) 100MB/s at most. >> > >> >> > Is there any other client on than that Windows VM on your Ceph cluster? >> >> Yes, another one instance but without load. >> >OK. >> > >> >> > Is Ceph understanding this now? >> >> > Other than that, the queue options aren't likely to do much good with >> >> > pure >> >> >HDD OSDs. >> >> >> >> I can't find those parameter in running config: >> >> ceph --admin-daemon /var/run/ceph/ceph-mon.block01.asok config show|grep >> >> "filestore_queue" >> > >> >These are OSD parameters, you need to query an OSD daemon. >> > >> >> "filestore_queue_max_ops": "3000", >> >> "filestore_queue_max_bytes": "1048576000", >> >> "filestore_queue_max_delay_multiple": "0", >> >> "filestore_queue_high_delay_multiple": "0", >> >> "filestore_queue_low_threshhold": "0.3", >> >> "filestore_queue_high_threshhold": "0.9", >> >> > That should be 512, 1024 really with one RBD pool. >> >> >> >> Yes, I know. Today for test I added scbench pool with 128 pg >> >> There are output status and osd tree: >> >> ceph status >> >> cluster 830beb43-9898-4fa9-98c1-ee04c1cdf69c >> >> health HEALTH_OK >> >> monmap e6: 3 mons at >> >> {block01=10.30.9.21:6789/0,object01=10.30.9.129:6789/0,object02=10.30.9.130:6789/0} >> >> election epoch 238, quorum 0,1,2 block01,object01,object02 >> >> osdmap e6887: 18 osds: 18 up, 18 in >> >> pgmap v9738812: 1280 pgs, 3 pools, 17440 GB data, 4346 kobjects >> >> 35049 GB used, 15218 GB / 50267 GB avail >> >> 1275 active+clean >> >> 3 active+clean+scrubbing+deep >> >> 2 active+clean+scrubbing >> >> >> >Check the ML archives and restrict scrubs to off-peak hours as well as >> >tune things to keep their impact low. >> > >> >Scrubbing is a major performance killer, especially on non-SSD journal >> >OSDs and with older Ceph versions and/or non-tuned parameters: >> >--- >> >osd_scrub_end_hour = 6 >> >osd_scrub_load_threshold = 2.5 >> >osd_scrub_sleep = 0.1 >> >--- >> > >> >> client io 5030 kB/s rd, 1699 B/s wr, 19 op/s rd, 0 op/s wr >> >> >> >> ID WEIGHT TYPE NAME UP/DOWN REWEIGHT PRIMARY-AFFINITY >> >> -1 54.00000 root default >> >> -2 27.00000 host cn802 >> >> 0 3.00000 osd.0 up 1.00000 1.00000 >> >> 2 3.00000 osd.2 up 1.00000 1.00000 >> >> 4 3.00000 osd.4 up 1.00000 1.00000 >> >> 6 3.00000 osd.6 up 0.89995 1.00000 >> >> 8 3.00000 osd.8 up 1.00000 1.00000 >> >> 10 3.00000 osd.10 up 1.00000 1.00000 >> >> 12 3.00000 osd.12 up 0.89999 1.00000 >> >> 16 3.00000 osd.16 up 1.00000 1.00000 >> >> 18 3.00000 osd.18 up 0.90002 1.00000 >> >> -3 27.00000 host cn803 >> >> 1 3.00000 osd.1 up 1.00000 1.00000 >> >> 3 3.00000 osd.3 up 0.95316 1.00000 >> >> 5 3.00000 osd.5 up 1.00000 1.00000 >> >> 7 3.00000 osd.7 up 1.00000 1.00000 >> >> 9 3.00000 osd.9 up 1.00000 1.00000 >> >> 11 3.00000 osd.11 up 0.95001 1.00000 >> >> 13 3.00000 osd.13 up 1.00000 1.00000 >> >> 17 3.00000 osd.17 up 0.84999 1.00000 >> >> 19 3.00000 osd.19 up 1.00000 1.00000 >> >> > Wrong way to test this, test it from a monitor node, another client node >> >> > (like your openstack nodes). >> >> > In your 2 node cluster half of the reads or writes will be local, very >> >> > much skewing your results. >> >> I have been tested from copmute node also and have same result. >> >> 80-100Mb/sec >> >> >> >That's about as good as it gets (not 148MB/s, though!). >> >But rados bench is not the same as real client I/O. >> > >> >> > Very high max latency, telling us that your cluster ran out of steam at >> >> some point. >> >> >> >> I copying data from my windows instance right now. >> > >> >Re-do any testing when you've stopped all scrubbing. >> > >> >> > I'd de-frag anyway, just to rule that out. >> >> >> >> >> >> >When doing your tests or normal (busy) operations from the client VM, run >> >> > atop on your storage nodes and observe your OSD HDDs. >> >> > Do they get busy, around 100%? >> >> >> >> Yes, high IO load (600-800 io). But this is very strange on SATA HDD. >> >> All HDD have own OSD daemon and presented in OS as hardware RAID0(each >> >> block node have hardware RAID). Example: >> > >> >Your RAID controller and its HW cache are likely to help with that speed, >> >also all of these are reads, most likely the scrubs above, not a single >> >write to be seen. >> > >> >> avg-cpu: %user %nice %system %iowait %steal %idle >> >> 1.44 0.00 3.56 17.56 0.00 77.44 >> >> Device: rrqm/s wrqm/s r/s w/s rkB/s wkB/s avgrq-sz avgqu-sz await r_await >> >> w_await svctm %util >> >> sdb 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 >> >> sdc 0.00 0.00 649.00 0.00 82912.00 0.00 255.51 8.30 12.74 12.74 0.00 1.26 >> >> 81.60 >> >> sdd 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 >> >> sde 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 >> >> sdf 0.00 0.00 761.00 0.00 94308.00 0.00 247.85 8.66 11.26 11.26 0.00 1.18 >> >> 90.00 >> >> sdg 0.00 0.00 761.00 0.00 97408.00 0.00 256.00 7.80 10.22 10.22 0.00 1.01 >> >> 76.80 >> >> sdh 0.00 0.00 801.00 0.00 102344.00 0.00 255.54 8.05 10.05 10.05 0.00 >> >> 0.96 76.80 >> >> sdi 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 >> >> sdj 0.00 0.00 537.00 0.00 68736.00 0.00 256.00 5.54 10.26 10.26 0.00 0.98 >> >> 52.80 >> >> >> >> >> >> > Check with iperf or NPtcp that your network to the clients from the >> >> > storage nodes is fully functional. >> >> The network have been tested by iperf. 950-970Mbit among all nodes in >> >> clustes (openstack and ceph) >> > >> >Didn't think it was that, one thing off the list to check. >> > >> >Christian >> > >> >Понедельник, 11 июля 2016, 10:58 +05:00 от Christian Balzer >> >< [email protected] >: >> >> > >> >> > >> >> >Hello, >> >> > >> >> >On Mon, 11 Jul 2016 07:35:02 +0300 K K wrote: >> >> > >> >> >> >> >> >> Hello, guys >> >> >> >> >> >> I to face a task poor performance into windows 2k12r2 instance running >> >> >> on rbd (openstack cluster). RBD disk have a size 17Tb. My ceph cluster >> >> >> consist from: >> >> >> - 3 monitors nodes (Celeron G530/6Gb RAM, DualCore E6500/2Gb RAM, >> >> >> Core2Duo E7500/2Gb RAM). Each node have 1Gbit network to frontend >> >> >> subnet >> >> >> od Ceph cluster >> >> > >> >> >I hope the fastest of these MONs (CPU and storage) has the lowest IP >> >> >number and thus is the leader. >> >> > >> >> >Also what Ceph, OS, kernel version? >> >> > >> >> >> - 2 block nodes (Xeon E5620/32Gb RAM/2*1Gbit NIC). Each node have >> >> >> 2*500Gb HDD for operation system and 9*3Tb SATA HDD (WD SE). Total 18 >> >> >> OSD daemons on 2 nodes. >> >> > >> >> >Two GbE ports, given the "frontend" up there with the MON description I >> >> >assume that's 1 port per client (front) and cluster (back) network? >> >> > >> >> >>Journals placed on same HDD as a rados data. I >> >> >> know that better using for those purpose separate SSD disk. >> >> >Indeed... >> >> > >> >> >>When I test >> >> >> new windows instance performance was good (read/write something about >> >> >> 100Mb/sec). But after I copied 16Tb data to windows instance read >> >> >> performance has down to 10Mb/sec. Type of data on VM - image and video. >> >> >> >> >> >100MB/s would be absolute perfect with the setup you have, assuming no >> >> >contention (other clients). >> >> > >> >> >Is there any other client on than that Windows VM on your Ceph cluster? >> >> > >> >> >> ceph.conf on client side: >> >> >> [global] >> >> >> auth cluster required = cephx >> >> >> auth service required = cephx >> >> >> auth client required = cephx >> >> >> filestore xattr use omap = true >> >> >> filestore max sync interval = 10 >> >> >> filestore queue max ops = 3000 >> >> >> filestore queue commiting max bytes = 1048576000 >> >> >> filestore queue commiting max ops = 5000 >> >> >> filestore queue max bytes = 1048576000 >> >> >> filestore queue committing max ops = 4096 >> >> >> filestore queue committing max bytes = 16 MiB >> >> > ^^^ >> >> >Is Ceph understanding this now? >> >> >Other than that, the queue options aren't likely to do much good with >> >> >pure >> >> >HDD OSDs. >> >> > >> >> >> filestore op threads = 20 >> >> >> filestore flusher = false >> >> >> filestore journal parallel = false >> >> >> filestore journal writeahead = true >> >> >> journal dio = true >> >> >> journal aio = true >> >> >> journal force aio = true >> >> >> journal block align = true >> >> >> journal max write bytes = 1048576000 >> >> >> journal_discard = true >> >> >> osd pool default size = 2 # Write an object n times. >> >> >> osd pool default min size = 1 >> >> >> osd pool default pg num = 333 >> >> >> osd pool default pgp num = 333 >> >> >That should be 512, 1024 really with one RBD pool. >> >> > http://ceph.com/pgcalc/ >> >> > >> >> >> osd crush chooseleaf type = 1 >> >> >> >> >> >> [client] >> >> >> rbd cache = true >> >> >> rbd cache size = 67108864 >> >> >> rbd cache max dirty = 50331648 >> >> >> rbd cache target dirty = 33554432 >> >> >> rbd cache max dirty age = 2 >> >> >> rbd cache writethrough until flush = true >> >> >> >> >> >> >> >> >> rados bench show from block node show: >> >> >Wrong way to test this, test it from a monitor node, another client node >> >> >(like your openstack nodes). >> >> >In your 2 node cluster half of the reads or writes will be local, very >> >> >much skewing your results. >> >> > >> >> >> rados bench -p scbench 120 write --no-cleanup >> >> > >> >> >Default tests with 4MB "blocks", what are the writes or reads from you >> >> >client VM like? >> >> > >> >> >> Total time run: 120.399337 >> >> >> Total writes made: 3538 >> >> >> Write size: 4194304 >> >> >> Object size: 4194304 >> >> >> Bandwidth (MB/sec): 117.542 >> >> >> Stddev Bandwidth: 9.31244 >> >> >> Max bandwidth (MB/sec): 148 >> >> > ^^^ >> >> >That wouldn't be possible from an external client. >> >> > >> >> >> Min bandwidth (MB/sec): 92 >> >> >> Average IOPS: 29 >> >> >> Stddev IOPS: 2 >> >> >> Max IOPS: 37 >> >> >> Min IOPS: 23 >> >> >> Average Latency(s): 0.544365 >> >> >> Stddev Latency(s): 0.35825 >> >> >> Max latency(s): 5.42548 >> >> >Very high max latency, telling us that your cluster ran out of steam at >> >> >some point. >> >> > >> >> >> Min latency(s): 0.101533 >> >> >> >> >> >> rados bench -p scbench 120 seq >> >> >> Total time run: 120.880920 >> >> >> Total reads made: 1932 >> >> >> Read size: 4194304 >> >> >> Object size: 4194304 >> >> >> Bandwidth (MB/sec): 63.9307 >> >> >> Average IOPS 15 >> >> >> Stddev IOPS: 3 >> >> >> Max IOPS: 25 >> >> >> Min IOPS: 5 >> >> >> Average Latency(s): 0.999095 >> >> >> Max latency(s): 8.50774 >> >> >> Min latency(s): 0.0391591 >> >> >> >> >> >> rados bench -p scbench 120 rand >> >> >> Total time run: 121.059005 >> >> >> Total reads made: 1920 >> >> >> Read size: 4194304 >> >> >> Object size: 4194304 >> >> >> Bandwidth (MB/sec): 63.4401 >> >> >> Average IOPS: 15 >> >> >> Stddev IOPS: 4 >> >> >> Max IOPS: 26 >> >> >> Min IOPS: 1 >> >> >> Average Latency(s): 1.00785 >> >> >> Max latency(s): 6.48138 >> >> >> Min latency(s): 0.038925 >> >> >> >> >> >> On XFS partitions fragmentation no more than 1% >> >> >I'd de-frag anyway, just to rule that out. >> >> > >> >> >When doing your tests or normal (busy) operations from the client VM, run >> >> >atop on your storage nodes and observe your OSD HDDs. >> >> >Do they get busy, around 100%? >> >> > >> >> >Check with iperf or NPtcp that your network to the clients from the >> >> >storage nodes is fully functional. >> >> > >> >> >Christian >> >> >-- >> >> >Christian Balzer Network/Systems Engineer >> >> > [email protected] Global OnLine Japan/Rakuten Communications >> >> > http://www.gol.com/ >> >> >> > >> > >> >-- >> >Christian Balzer Network/Systems Engineer >> > [email protected] Global OnLine Japan/Rakuten Communications >> > http://www.gol.com/ >> > > >-- >Christian Balzer Network/Systems Engineer >[email protected] Global OnLine Japan/Rakuten Communications >http://www.gol.com/
_______________________________________________ ceph-users mailing list [email protected] http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com