> 在 2016年9月26日,下午10:44,Eugen Block <[email protected]> 写道:
>
> What I have tried is to manually repair single PGs as described in [1]. But
> some of the broken PGs have no entries in the log file so I don't have
> anything to look at.
> In case there is one object in one OSD but is missing in the other. how do I
> get that copied back there? Everything I've tried so far didn't accomplish
> anything except the decreasing number of scrub errors, but they are
> increasing again, so no success at all.
met before in my case, no error in the log too,
like this back to normal:
1. offline the OSD(with inconsistent pgid in the osd) and marked as out,
waiting for the completion of data synchronization, and then delete the OSD
2. manual repair again, waiting for a period of time, the cluster can be
returned to normal
3. in the end, then re join the deletion of the OSD.
Good Luck!