Hey guys,
we're evaluating ceph at the moment for a bigger production-ready
implementation. So far we've had some success and
some problems with ceph. In combination with Proxmox CEPH works quite well, if
taken out of the box. I've tried to coverup my questions
with existing answers and solutions but i still find some things unclear. Here
are the things i'm having problems with:
1. The first question is just for my understanding: How does CEPH account
failure domains? For what i've read by now is
that i create a new CRUSH-Map with for example 2 datacenters, each DC has a
rack and in this rack there is a chassis with nodes.
By using an own CRUSH-Map CEPH will "see" it and deal with the data
automatically. What i am missing here is some more possible adjustment.
For example i want to define that by using a replica of 3 i want CEPH to store
the data 2 times in datacenter A and one time in datacenter B. Further
more i want read-access exclusivly within 1 datacenter (if possible and data is
available) to keep rtt low. Is this possible?
2. I've build my own CRUSH-Map and tried to get it working. No success at
all. I'm literally "done with this s..." :) thats why im here right now. Here
is the state
of the cluster:
cluster 42f04e55-0a3f-4644-8543-516cd46cd4e9
health HEALTH_WARN
79 pgs degraded
262 pgs stale
79 pgs stuck degraded
262 pgs stuck stale
512 pgs stuck unclean
79 pgs stuck undersized
79 pgs undersized
monmap e8: 6 mons at
{0=192.168.40.20:6789/0,1=192.168.40.21:6789/0,2=192.168.40.22:6789/0,3=192.168.40.23:6789/0,4=192.168.40.24:6789/0,5=192.168.40.25:6789/0}
election epoch 86, quorum 0,1,2,3,4,5 0,1,2,3,4,5
mdsmap e2: 0/0/1 up
osdmap e212: 6 osds: 5 up, 5 in; 250 remapped pgs
pgmap v366013: 512 pgs, 2 pools, 0 bytes data, 0 objects
278 MB used, 900 GB / 901 GB avail
250 active+remapped
183 stale+active+remapped
79 stale+active+undersized+degraded+remapped
Here the config:
ID WEIGHT TYPE NAME UP/DOWN REWEIGHT PRIMARY-AFFINITY
-27 1.07997 root default
-25 0.53998 datacenter datacenter1
-23 0.53998 chassis chassis1
-1 0.17999 blade blade3
0 0.17999 osd.0 down 0 1.00000
-2 0.17999 blade blade4
1 0.17999 osd.1 up 1.00000 1.00000
-3 0.17999 blade blade5
2 0.17999 osd.2 up 1.00000 1.00000
-26 0.53999 datacenter datacenter2
-24 0.53999 chassis chassis2
-17 0.17999 blade blade17
3 0.17999 osd.3 up 0.95001 1.00000
-18 0.17999 blade blade18
4 0.17999 osd.4 up 1.00000 1.00000
-19 0.17999 blade blade19
5 0.17999 osd.5 up 1.00000 1.00000
I simply cant get osd.0 back up. I took it offline, out, reinserterd, resetup,
deleted the osd configs, remade them, no success
whatsoever. IMHO the documentation on this part is a bit "lousy" so im missing
some points of information here, sorry folks.
3. Last but not least i would like to know whether it is a good idea to
have the data and config network instead on 2 dedicated nics on 2 dedicated
vlans. Our
Hardware is redundant and we got 10GIG Fibreoptics inhouse and 80 GIG between
the two datacenters. The data-vlan is using jumbo frames while the others dont.
4. Do you guys have somekind of "best practice"-book available for large
scale deployments? 20+ Servers up to 100+ and 1000+
Regards
Florian