Hi,
I got a ceph cluster where I'm getting a OSD_OUT_OF_ORDER_FULL health
error, even though it appears that it is in order --
full_ratio
0.99
backfillfull_ratio 0.97
nearfull_ratio 0.98
These don't seem like a mistake to me but ceph is complaining --
OSD_OUT_OF_ORDER_FULL full ratio(s) out of order
backfillfull_ratio (0.97) < nearfull_ratio (0.98),
increased
osd_failsafe_full_ratio (0.97) < full_ratio (0.99), increased
_______________________________________________
ceph-users mailing list
[email protected]
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com