Hello Ceph Users,
We have added more ssd storage to our ceph cluster last night. We added 4 x 1TB
drives and the available space went from 1.6TB to 0.6TB ( in `ceph df` for the
SSD pool ).
I would assume that the weight needs to be changed but I didn't think I would
need to? Should I change them to 0.75 from 0.9 and hopefully it will rebalance
correctly?
Your hosts is imbalanced.
You should have weight of your hosts the same or average.
At this time NAS-AUBUN-RK2-CEPH08 & NAS-AUBUN-RK2-CEPH07 have crush
weight 105.51169, other hosts weighted half or less.
What you can do with this?
- Decrease your crush weight for new 1Tb drives. Usage of this drive
space will be less;
- Replace your old drives to 1Tb drives;
- Balance your drives between hosts - 1x1Tb, 2x500Gb, etc... per host is
better that 4x1Tb per host against 6x500Gb per host.
k
_______________________________________________
ceph-users mailing list
[email protected]