I really don’t understand your problem; troll? S
From: Ghansham Sangar <[email protected]> Date: Tuesday, 31 December 2019 at 10:33 PM To: Simon Wood <[email protected]> Cc: "[email protected]" <[email protected]> Subject: Re: [CF-CONVENTIONS] Reg multi-band radiometric swath data Agree with you to quite some extent. Can we create a dataset with single dimension say 'scan' and value of scan=6000 and store 60000 values in that dataset with 10 pixels per scan? That is the whole point of discussion. Regards Ghansham On Tue, Dec 31, 2019, 08:23 Simon Wood <[email protected]<mailto:[email protected]>> wrote: Ghansham, For a starting point I would suggest following example 6 in section 2.4.1, with: time = <no of scans> or UNLIMITED? scan = 6000 band = 4 I’m not convinced ‘scan’ is the most intuitive dimension name here, but you can swap that for something better as you see fit (e.g. ncols). Hope this helps, Simon From: Discussion around CF Conventions <[email protected]<mailto:[email protected]>> on behalf of Ghansham Sangar <[email protected]<mailto:[email protected]>> Reply to: Ghansham Sangar <[email protected]<mailto:[email protected]>> Date: Tuesday, 31 December 2019 at 3:06 PM To: "[email protected]<mailto:[email protected]>" <[email protected]<mailto:[email protected]>> Subject: [CF-CONVENTIONS] Reg multi-band radiometric swath data With reference to the below link: https://github.com/Unidata/EC-netCDF-CF/blob/master/swath/swath.adoc<https://aus01.safelinks.protection.outlook.com/?url=https%3A%2F%2Fgithub.com%2FUnidata%2FEC-netCDF-CF%2Fblob%2Fmaster%2Fswath%2Fswath.adoc&data=02%7C01%7CSimon.Wood%40niwa.co.nz%7C28fcade7268344cec7f708d78dd472f0%7C41caed736a0c468aba499ff6aafd1c77%7C0%7C1%7C637133815951957665&sdata=1H7MPfl9xwJhUrU3PuHErqwDos%2FgmJFA0tm%2Bm8YsTJA%3D&reserved=0> I have following query: for multi band swath data, the shape is 'time scan band'. I have a linear ccd array with say 6000 pixels across track for say each of the 4 bands. Every scan has a time of acquisition associated. All 6000 pixels share same time of acquisition. Now I want to store this as per cf standards. Kindly guide me on this. Regards Ghansham [Image removed by sender.]<https://www.niwa.co.nz/> Simon Wood Senior Research Software Engineer +64-4-386-0877 | +64-21-891-502 National Institute of Water & Atmospheric Research Ltd (NIWA) 301 Evans Bay Parade Hataitai Wellington New Zealand Connect with NIWA: niwa.co.nz<https://www.niwa.co.nz> Facebook<https://aus01.safelinks.protection.outlook.com/?url=https%3A%2F%2Fwww.facebook.com%2Fnzniwa&data=02%7C01%7CSimon.Wood%40niwa.co.nz%7C28fcade7268344cec7f708d78dd472f0%7C41caed736a0c468aba499ff6aafd1c77%7C0%7C0%7C637133815951967663&sdata=0xZ8ML%2BCXMWbYOTseQ8i6qbvKpwxrRoZ6zvyLDXWnu0%3D&reserved=0> LinkedIn<https://aus01.safelinks.protection.outlook.com/?url=https%3A%2F%2Fwww.linkedin.com%2Fcompany%2Fniwa&data=02%7C01%7CSimon.Wood%40niwa.co.nz%7C28fcade7268344cec7f708d78dd472f0%7C41caed736a0c468aba499ff6aafd1c77%7C0%7C1%7C637133815951977662&sdata=egMYK%2FAkAKLDgQ%2B658MPtgKm6AVlCSEdSU5YPdpdsRk%3D&reserved=0> Twitter<https://aus01.safelinks.protection.outlook.com/?url=https%3A%2F%2Ftwitter.com%2Fniwa_nz&data=02%7C01%7CSimon.Wood%40niwa.co.nz%7C28fcade7268344cec7f708d78dd472f0%7C41caed736a0c468aba499ff6aafd1c77%7C0%7C0%7C637133815951977662&sdata=44rKaDrQ2bUB%2FW2vt4OSXcplbCmwuBLHgI8%2BUCOZ8Ng%3D&reserved=0> Instagram<https://aus01.safelinks.protection.outlook.com/?url=https%3A%2F%2Fwww.instagram.com%2Fniwa_science&data=02%7C01%7CSimon.Wood%40niwa.co.nz%7C28fcade7268344cec7f708d78dd472f0%7C41caed736a0c468aba499ff6aafd1c77%7C0%7C0%7C637133815951987653&sdata=tOAZcRzEdniqFbaBhqcdwofx7bE9aPJV61wdRDSmiBI%3D&reserved=0> To ensure compliance with legal requirements and to maintain cyber security standards, NIWA's IT systems are subject to ongoing monitoring, activity logging and auditing. This monitoring and auditing service may be provided by third parties. Such third parties can access information transmitted to, processed by and stored on NIWA's IT systems
