DataDirect 3.2, add "4096 null" under load.

-nathan strutz

-----Original Message-----
From: Calvin Ward [mailto:[EMAIL PROTECTED]
Sent: Friday, October 17, 2003 2:07 PM
To: CF-Talk
Subject: DataDirect JDBC drivers (shipped with CFMX)..

Apparently whichever way you go there's going to be an issue to deal with on
the JDBC drivers, has anyone else worked through these? This is on Windows
2000, with SQL Server 2000.

===============================

DataDirect 3.1 Old (CFMX Updater 3)

- cfstoredproc: Could not find prepared statement with handle

DataDirect 3.1 New (CFMX 6.1)

- 100% CPU Utilization

DataDirect 3.2

- no more data to read

- sql insufficient memory to complete this query

===============================

Thanks,

Calvin