One minor nit below, otherwise LGTM. I'll let Richard sign off on the serialization stuff though.
> Index: include/clang/Sema/Sema.h > =================================================================== > --- include/clang/Sema/Sema.h (revision 208334) > +++ include/clang/Sema/Sema.h (working copy) > @@ -333,6 +333,11 @@ > /// VisContext - Manages the stack for \#pragma GCC visibility. > void *VisContext; // Really a "PragmaVisStack*" > > + /// \brief This represents the last location of a "#pragma clang optimize > off" > + /// directive if such a directive has not been closed by an "on" yet. If > + /// optimizations are currently "on", this is set to an invalid location. > + SourceLocation OptimizeOffPragmaLocation; > + > /// \brief Flag indicating if Sema is building a recovery call expression. > /// > /// This flag is used to avoid building recovery call expressions > @@ -7228,6 +7233,23 @@ > /// the appropriate attribute. > void AddCFAuditedAttribute(Decl *D); > > + /// \brief Called on well formed \#pragma clang optimize. > + void ActOnPragmaOptimize(bool On, SourceLocation PragmaLoc); > + > + /// \brief Get the location for the currently active "\#pragma clang > optimize > + /// off". If this location is invalid, then the state of the pragma is > "on". > + SourceLocation getOptimizeOffPragmaLocation(); This function can be const and implemented inline. ~Aaro On Thu, May 8, 2014 at 12:43 PM, Dario Domizioli <[email protected]> wrote: > Hello again! > > I have now extended the patch with support for serialization of the state of > the pragma (for PCHs). I have followed a similar pattern to the one used for > the floating point pragmas and the diagnostic pragmas. > I have added a PCH test that verifies that if a "#pragma clang optimize off" > is still active at the end of a PCH then a source file compiled including > the PCH will behave as if the pragma was specified in the source (as it > happens with normal headers). The test is modeled after the pragma > diagnostics test. > > I hope the new attached patch covers the issue that was raised by Richard... > but I welcome any feedback. I might have missed something. > > Cheers, > Dario Domizioli > SN Systems - Sony Computer Entertainment Group > > > > > > > > > On 7 May 2014 18:41, Dario Domizioli <[email protected]> wrote: >> >> >> Thanks Aaron! >> >>> Patch LGTM, modulo Richard's comments about serialization (I worried >>> about the same thing, and my preference is for the patch to be >>> all-inclusive when feasible, but Richard is welcome to weigh in). I >>> have no strong opinions on whether it should be one diagnostic or two. >> >> >> I will wait for Richard's comments then; meanwhile I'll keep working on >> the serialization issue. >> >> As for the diagnostics, I think that having two might make it easier to >> extend the "unexpected" case if the pragma gains new functionality in the >> future, while the "missing" case is unlikely to change... although the >> %select is quite powerful so I haven't got a strong preference either. >> >> Cheers, >> Dario Domizioli >> SN Systems - Sony Computer Entertainment Group >> >> > _______________________________________________ cfe-commits mailing list [email protected] http://lists.cs.uiuc.edu/mailman/listinfo/cfe-commits