On Thursday 13 February 2003 09:14 am, Robert Ritchey wrote: > Hi Matthias, > OK, I got the data sheet. Its still not clear to me if the zener goes > between the gate and the 5V input or the gate and ground? Even > with the data sheet I don't quite understand how a Triac works.
A Triac is two inverse parallel SCR's on the same die, with a a shared gate lead. >From experiance I swore that I would never design in a triac again. They are to prone to false firing (dV/dt type issues). My application was a phase control on a noise line. You should not have that problem with your protection circuit, I hope. For every ones future reference use real inverse parallel SCR's or Tecor's Altnistors, that are inverse parallel SCR's on the same package. Look at the dV/dT specs to see why I say this... -- Author: Bob Paddock INET: [EMAIL PROTECTED] Fat City Network Services -- 858-538-5051 http://www.fatcity.com San Diego, California -- Mailing list and web hosting services --------------------------------------------------------------------- To REMOVE yourself from this mailing list, send an E-Mail message to: [EMAIL PROTECTED] (note EXACT spelling of 'ListGuru') and in the message BODY, include a line containing: UNSUB CHIPDIR-L (or the name of mailing list you want to be removed from). You may also send the HELP command for other information (like subscribing).