On Wed, Jan 18, 2017 at 08:41:03PM -0800, Denny Page wrote:
> Tx -> Rx timestamp:
>   Uncompensated                        3175ns  (stddev 110ns)
>   Compensated                          3175ns
> 
> Connection types:       Expected        Error
>   Regular switch          6721ns      -3546ns
>   Cut-through switch      2081ns       1094ns
>   loopback cable             1ns       3174ns
> 
> Intel’s predicted result is 3177ns.

Interesting. So 3174ns is what txcomp+rxcomp should be for the i211?

-- 
Miroslav Lichvar

-- 