--- doc/chrony.conf.adoc | 9 +++++++++ 1 file changed, 9 insertions(+) diff --git a/doc/chrony.conf.adoc b/doc/chrony.conf.adoc index 5c85959..55d23e1 100644 --- a/doc/chrony.conf.adoc +++ b/doc/chrony.conf.adoc @@ -552,6 +552,15 @@ Set the minimum number of samples kept for this source. This overrides the *maxsamples* _samples_::: Set the maximum number of samples kept for this source. This overrides the <<maxsamples,*maxsamples*>> directive. +*tai* _tai_::: +This option can be set to indicate that the time on the given +reference clock is kept in TAI and that chrony should attempt to apply +the current TAI-UTC offset to samples taken from this refclock. To +use this, the *leapsectz* directive must be used as chrony uses the +timezone files to compute the current TAI-UTC offset. If the +*leapsectz* directive is not in use, a warning will be logged and no +offset will be applied. This option does not make sense if the given +refclock is only being used for PPS input. [[manual]]*manual*:: The *manual* directive enables support at run-time for the -- 2.13.5
-- To unsubscribe email chrony-dev-requ...@chrony.tuxfamily.org with "unsubscribe" in the subject. For help email chrony-dev-requ...@chrony.tuxfamily.org with "help" in the subject. Trouble? Email listmas...@chrony.tuxfamily.org.