On 5/9/2017 12:52 PM, Bill Unruh wrote:
Note that the main problem with pps is that it tells chrony exactly when
the
transition at the top of the second takes place, it does not tell it which
second that was.


So for PPS to work, there has to be a second time source to identify the second. What happens if you start up the system without an internet connection (a very real possibility in my case)? Would chrony use the RTC to figure out the second?

Deven

--
To unsubscribe email chrony-users-requ...@chrony.tuxfamily.org with "unsubscribe" in the subject. For help email chrony-users-requ...@chrony.tuxfamily.org with "help" in the subject.
Trouble?  Email listmas...@chrony.tuxfamily.org.