Hi!

In my use case I use tcpdump and other tools to capture and record network
traffic. This traffic is stored with a attached hardware timestamp form the
NIC PHCs. I want these timestamps to be synchronized as close as possible
to UTC.

In some data centers I have access to PTP and can easily synchronize all
clocks on each servers to UTC. In some data centers I need to use NTP and
chrony.

The problem is that chrony only synchronizes the system clock to NTP, not
the rest of the PHC in the server. I use
https://github.com/exablaze-oss/exanic-software/blob/master/util/exanic-clock-sync.c
to synchronize the NIC PHCs to the system clock. I also use chrony hardware
timestamping. This causes a synchronization loop that can potentially lead
to oscillations. If I use the default min/max poll intervals I see no
oscillations in practice. This is probably because exanic-clock-sync servo
runs at much higher frequency (~10s).

When I decrease the chrony poll interval I end up with oscillations.

Are there any plans for making chrony also synchronize the NIC PHCs? It
seems to me that NIC PHCs are become more prevalent and the only way to
reliably synchronize them to the system clock is to have the system wide
clock servo (NTP or chrony) perform that task.

Regards,
Erik