On Fri, Dec 18, 2020 at 04:11:28AM +0000, Baby, Pradeep wrote:
> Hi Users,
> 
> What option will give the offset value? How these are different?
> 
> 'chronyc tracking' ==> Last Offset

This is the offset of the NTP clock at its last update using a
combined value from all sources selected for synchronization.

> or
> 'chronyc sources'==> Last sample

This is the last NTP measurement for each source. No processing.

> or
> Chronyc sourcestats ==> Offset

This is a processed offset from up to 64 measurements for each
source.

-- 
Miroslav Lichvar


-- 