Hi,
I created an issue on the gpsd tracker:
https://gitlab.com/gpsd/gpsd/-/issues/274. The gpsd documentation on
using chrony disagrees with the chrony documentation on using gpsd. I am
guessing that the chrony documentation is the correct one, but am
uncertain. If someone more knowledgeable than me has anything to add,
please do.
The delay and offset seem wrong. I turned them off and am getting
timings that are almost the same for the GPS (PPS) and NMEA devices. I
don't know what is going on there. I could also monitor the timings for
a while to get better timings.
Also, the device path given by chrony is out of date and the one given
by gpsd works: that is "/run/chrony.XXXX.sock" instead of
"/var/run/chrony.clk.XXXX.sock". If I am wrong about the paths, I don't
know how chrony works, but only the former works for me.
--