On Fri, Jul 19, 2024 at 05:27:41AM +0000, 邹林志08963 wrote: > > I'm not sure what exactly you are pointing out here, but in our case > > we care only about the lower bound to increase the number of runs when > > it's lower than expected for the number of samples. If the number of > > runs is too high, we don't care. > > well, when the formula is " runs = mu - sqrt(var) * Z ", > the critical_runs will be:
> and when the formula is " runs = mu + sqrt(var) * Z ", > I just wonder which one is correct. The first one. We care about the lower end of the interval. -- Miroslav Lichvar -- To unsubscribe email chrony-users-requ...@chrony.tuxfamily.org with "unsubscribe" in the subject. For help email chrony-users-requ...@chrony.tuxfamily.org with "help" in the subject. Trouble? Email listmas...@chrony.tuxfamily.org.