On Thu, Oct 24, 2024 at 01:02:40PM +0000, chengyechun wrote: > MS Name/IP address Stratum Poll Reach LastRx Last sample > > =============================================================================== > > ^x 9.82.178.244 10 2 17 1 +3788ns[+3788ns] +/- > 147us > > ^x 9.82.165.239 10 2 17 1 -65ms[ -65ms] +/- > 152us
These two sources don't agree with each other. They are about 65 milliseconds apart. chronyd doesn't know which one (if any) is correct. That's why normally is recommended to have at least three sources. You can mark one with the "trust" option to force chronyd to select it. -- Miroslav Lichvar -- To unsubscribe email chrony-users-requ...@chrony.tuxfamily.org with "unsubscribe" in the subject. For help email chrony-users-requ...@chrony.tuxfamily.org with "help" in the subject. Trouble? Email listmas...@chrony.tuxfamily.org.