Hello all, Many thanks for help in the past. I'm hoping someone will have something enlightening about this. TAC and Bugfinder are turning up little, so I dunno what the chances are, but here it is...
I'll paste a bunch of version and module info at the bottom of this email, so as not to clutter the part that peple are more likely to read here. Essentially, what's happening is that when power is lost to Power Supply 1, the router crashes. [System returned to ROM by power-on (SP by error - a Software forced crash, PC 0x4011EF5C)] Power loss to PS2 doesn't cause it. If I swap the two power supplies, it still does it on PS1. In other words, if the power is lost to "bay" 1, for lack of a better word, it crashes. Has anyone ever run into anything like this? One thing to note is that the input AC appears to be a bit low. I don't know if that could contribute. Thanks much. All the relevant info that's not overly verbose follows. Here are the modules (modified "show mod"): Mod Ports Card Type Model --- ----- -------------------------------------- ------------------ 1 2 Catalyst 6000 supervisor 2 (Active) WS-X6K-SUP2-2GE 2 8 8 port 1000mb ethernet WS-X6408-GBIC 3 48 48 port 10/100 mb RJ-45 ethernet WS-X6248-RJ-45 Mod Sub-Module Model --- --------------------------- --------------- 1 Policy Feature Card 2 WS-F6K-PFC2 1 Cat6k MSFC 2 daughterboard WS-F6K-MSFC2 A show ver: Cisco Internetwork Operating System Software IOS (tm) c6sup2_rp Software (c6sup2_rp-PSV-M), Version 12.1(19)E1, EARLY DEPLOYMENT RELEASE SOFTWARE (fc2) TAC Support: http://www.cisco.com/tac Copyright (c) 1986-2003 by cisco Systems, Inc. Compiled Sun 29-Jun-03 22:45 by nmasa Image text-base: 0x40008C00, data-base: 0x41814000 ROM: System Bootstrap, Version 12.2(17r)S1, RELEASE SOFTWARE (fc1) BOOTLDR: c6sup2_rp Software (c6sup2_rp-PSV-M), Version 12.1(19)E1, EARLY DEPLOYMENT RELEASE SOFTWARE (fc2) SEABD1 uptime is 1 week, 1 day, 21 hours, 43 minutes Time since SEABD1 switched to active is 1 week, 1 day, 21 hours, 42 minutes System returned to ROM by power-on (SP by error - a Software forced crash, PC 0x4011EF5C) System restarted at 14:20:22 PDT Tue May 22 2007 System image file is "sup-bootflash:c6sup22-psv-mz.121-19.E1.bin" cisco WS-C6509 (R7000) processor (revision 3.0) with 458752K/65536K bytes of memory. Processor board ID SAL0730H93F R7000 CPU at 300Mhz, Implementation 39, Rev 3.3, 256KB L2, 1024KB L3 Cache Last reset from power-on X.25 software, Version 3.0.0. Bridging software. 2 Virtual Ethernet/IEEE 802.3 interface(s) 48 FastEthernet/IEEE 802.3 interface(s) 10 Gigabit Ethernet/IEEE 802.3 interface(s) 381K bytes of non-volatile configuration memory. 32768K bytes of Flash internal SIMM (Sector size 512K). Configuration register is 0x2102 A "show env status power-supply X" shows the following for PS1 and PS2 power-supply X: power-supply X fan-fail: OK power-supply X power-input: AC low power-supply X power-output-fail: OK Thanks, Rick Kunkel _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/