Tom Storey wrote: > > On one particular PC I have cannot auto negotiate and cannot be set to > 100/full without producing errors. I have to run it in 100 half. At > least this one is only a PC. Its got a Broadcom NIC. > > My suggestion would be, if you can spare two ports on the switch, to > create a VLAN and stick the two interfaces that would normally connect > directly to each other into that VLAN. Otherwise, try different cables > between the two, set the port to 100/half, and try different > interfaces if you can. > > I may have other issues with the PC above, such as a dodgy cable. I > havnt gone so far to test that out yet as its bandwidth requirements > are low, 100/half does just fine.
I had an iMac that only liked 10/full on a cat 2924xl-en. Any other mode would produce CRC errors. Not 10/half, not 100 anything, only 10/full. ~Seth _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/