First thing I tried after getting the err-disable :-)
It works fine in the lab, but for production configuration I decided to
stick with the GLC-T GBIC option and use CAB-SFP-50CM= for connectivity
between 3560's only.

-----Original Message-----
From: Robert Hass [mailto:[EMAIL PROTECTED] 
Sent: Tuesday, February 12, 2008 5:05 AM
To: Tolstykh, Andrew
Cc: [email protected]
Subject: Re: [c-nsp] CAB-SFP-50CM= question

On Feb 12, 2008 5:21 AM, Tolstykh, Andrew <[EMAIL PROTECTED]>
wrote:
> The interface will end up in the err-disabled state due to the
> "unsupported gbic detected" message, at least that's what I got in the
> lab when I attempted to interconnect 3560's and 3750's with 2960's.

Can you try to add below commands:

service unsupported-transceiver
no errdisable detect cause gbic-invalid
no errdisable detect cause sfp-config-mismatch

and interconnect above switches again ?