Hey guys, I've ran into a ridiculous problem that has me completely stumped.
Network is a standard edge/core/access/distribution network comprised of 7206,6509-sup7203bxls, 3550s&3750s, and 3550s/2950s, respectively. Distribution is pure OSPF, with 226 routes currently in area 0, while the cores & edges run full mesh bgp. The cores originate defaults for the distribution layer, distribution layer carries all of the customer gateways and communicates those networks to OSPF. The distribution 3550-12G in question is running c3550-ipservices-mz.122-25.SEB4.bin. It's configured with 22 VSIs, carries all of Area 0 (226 routes), and has 354 mac addresses listed and just shy of 300 arp entries. Average traffic through the switch is approximately 120mbps. Not very loaded. This switches decided to randomly stop routing traffic two two completely separate VSIs (vlan 602, & vlan 149). These two VLANs are attached to the same port & downstream access switch, G0/4 and a 2960. The Internet can see the VSI IP addresses without issue, OSPF still advertises the routes without issue, everything is great up to the switch. Hosts attached to the 3550-12G are able to see their appropriate VSI gateway IP, but cannot see anything past it. Attached hosts are, however, able to see all of the other 21 VSI IP addresses on the switch -- just nothing off of the switch. No traffic is able to pass from off-switch/Internet to affected attached hosts, period. Resolution was to move the VSI/customer gateway to a different distribution switch. Although the affected/broken 3550-12G is still in the switching path, it does Layer 2 forwarding without issue -- just that those 2 VSIs just stopped forwarding traffic. So this morning, we lost two more networks, the primary and secondary IP address on a VSI for a completely different customer (vlan 609). On a lark, I clear arp'd and the two networks came back, but two other different VSIs went down (vlan 122, 167)! The only thing that all of the VSIs have in common is that they are all servicing customers attached to the 3550-12G's port G0/4. As mentioned earlier, there was a 2960 switch attached to G0/4, which has been replaced to no avail. Host configuration on affected VSI makes no difference - swapping in different servers, my laptop, etc, all yield the same problem. However, as of right now, if I plug my laptop into an access switch on g0/7 configured for the same now-broken vlan 167, it works just fine. It's almost as if the VSI's dealing specifically with g0/4 were having problems. Fearing a broken g0/4 <-> 2960 trunk, my config has been reduced to 4 lines, no change in service: ! interface GigabitEthernet0/4 description down_acc12.fac01.cos switchport trunk encapsulation dot1q switchport mode trunk load-interval 30 ! If I move the VSI & Gateway to different distribution switch, it works fine. If I move the access to a different port, it works fine. I have not reloaded the switch yet, as there is some other stuff on there that I don't want to incur 3-4 minutes of downtime on -- but I am fearing that the problem may jump and cause more harm. Am I dealing with a randomly screwed up g0/4 that's smoking VSIs (how?), a buggy IOS that does this or ???. I've been searching the Internet the world over and would love to hear some ideas and anecdotes. Thanks for reading my wall of text, Randal _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/