howdy ho,

we have some transit interfaces taht are GIG E interfaces on CISCO 7500
and 7600 boxes. these interfaces run at most at around 300 Meg.

The current queuing scheme on them is FIFO.

we have some operational folk who are making sounds that they want the
queuing to be WFQ as these boxes are pushing a mix of internet traffic and
VOIP packets (RTP packets)

My feelings are to leave the queuing as FIFO but was wondering if others
had some feelings or expierence in this

thanking you in advance for any thoughts or info

later



---------------------------------------------------------------------
Knowledge speaks, but wisdom listens.

Nic Tjirkalli