howdy ho,
we have some transit interfaces taht are GIG E interfaces on CISCO 7500 and 7600 boxes. these interfaces run at most at around 300 Meg. The current queuing scheme on them is FIFO. we have some operational folk who are making sounds that they want the queuing to be WFQ as these boxes are pushing a mix of internet traffic and VOIP packets (RTP packets) My feelings are to leave the queuing as FIFO but was wondering if others had some feelings or expierence in this thanking you in advance for any thoughts or info later --------------------------------------------------------------------- Knowledge speaks, but wisdom listens. Nic Tjirkalli Verizon Business South Africa Network Strategy Team Verizon Business is a brand of Verizon South Africa (Pty) Ltd. This e-mail is strictly confidential and intended only for use by the addressee unless otherwise indicated. Company Information:http:// www.verizonbusiness.com/za/contact/legal/ This e-mail is strictly confidential and intended only for use by the addressee unless otherwise indicated. _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/