When you tested it in SXH were you using the /vrf switch command or just normal netflow? Did you have your mls flow mask set to something other than null?
________________________________________ From: Phil Mayers [[email protected]] Sent: Saturday, February 21, 2009 6:30 AM To: Mike Louis Cc: [email protected] Subject: Re: [c-nsp] Netflow VRF Command Support in SXI On Fri, Feb 20, 2009 at 06:59:56PM +0000, Mike Louis wrote: >I can't use > >ip flow-export destination x.x.x.x 9995 vrf VRFNAME > >command in SXI. I have heard it was available in SXH? Did it get left out in >12.2(33)SXI? It seems so - I tested it in SXH but it's not present in SXI for me either. HOWEVER - when I tested it in SXH, it was useless - only software-switched flows were exported, it did not seem to work for hardware-switches flows. Perhaps that's why it was removed - maybe it was an unintentional inclusion in SXH? Note: This message and any attachments is intended solely for the use of the individual or entity to which it is addressed and may contain information that is non-public, proprietary, legally privileged, confidential, and/or exempt from disclosure. If you are not the intended recipient, you are hereby notified that any use, dissemination, distribution, or copying of this communication is strictly prohibited. If you have received this communication in error, please notify the original sender immediately by telephone or return email and destroy or delete this message along with any attachments immediately. _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/