Although i haven't met this, it might mean that the EVC frame matching config (the "encapsulation dot1q xxx" under the
service instance) is not "converted" into the appropriate TCAM entry in the ES card. A possible result would be that
frames that should be forwarded through this service instance, are either not forwarded at all or forwarded through a
less specific match criterion of another service instance.
In any case, your account SE should be able to provide you with more -internal-
details about this bug.
Regards,
Tassos
David Freedman wrote on 03/06/2009 18:32:
Has anybody come across this and if so are there any known workarounds?
Am keen to know under what circumstances an EFP does not get programmed
to the card, if anybody has any more information on this would be
appreciative of it online or offline.
Regards,
David Freedman
_______________________________________________
cisco-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/