Jeff Bacon wrote:
How are the ports that are on the supervisor module hooked into the
fabric/PFC? Are they at any significant advantage or disadvantage
compared to ports on linecards?

IIRC they're bus-attached ports on the plain sup720. I think they're fabric-attached on the sup720-10g.

They're obviously bus-attached on the sup32 since it lacks a fabric.

This matters for putting the box in dCEF-only mode, which helps some types of sup failover; see the first few items in:

http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/ios/12.2SX/configuration/guide/nsfsso.html#wp1105901

But, since you're primarily concerned with the sup32 that's not relevant.

I'm not hugely familiar with the sup32 but my understanding is that it lacks a fabric completely, and that the PFC and onboard ports are all attached to the bus. Perhaps someone else can comment.
_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to