Make sure you have the bootvar's set right and the config register also correct on both SUP's, as I once had a SUP2 that wouldn't boot, just to find out the confreg on the spare was not right, so it was just dropping to ROMMON..
--- Howard Leadmon > -----Original Message----- > From: [email protected] [mailto:cisco-nsp- > [email protected]] On Behalf Of Security Team > Sent: Thursday, September 10, 2009 5:44 PM > To: [email protected] > Subject: [c-nsp] Weird Cat 6500 SUP2 problem > > I am setting up a 6509 with SUP2's in RPR+ redundancy mode. When I cycle > power on both supplies, the top SUP2 comes up fine. But the bottom one is > stuck in rommon > > If I type "b" to boot the second one it comes up fine. > > Am I doing something stupid? > > Thx, > CJ > > > > _______________________________________________ > cisco-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/cisco-nsp > archive at http://puck.nether.net/pipermail/cisco-nsp/ _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/