Hi all, I've got some ME3400Gs with CWDM SFPs, and some of them are causing errors to be logged:
Jan 5 14:21:30.087 PST: %SFF8472-5-THRESHOLD_VIOLATION: Gi0/1: Voltage high warning; Operating value: 3.56 V, Threshold value: 3.50 V. These SFPs are not Cisco official, which I think is the source of the errors. Is this a serious problem? The SFPs appear to work just fine. If this is purely cosmetic, does anyone know how to suppress these log messages? Thanks! -- Jared _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/