On 15/03/2010 16:26, Jirí Procházka wrote: > When traffic on this link reaches aproximately 6Gbps, latence to servers > gets rapidly worse (about 100-150ms, about 2ms before)
the 6708 card has 200 megs of buffers per port. doing the sums, this works out at about 160ms of latency, assuming you're seeing a 10Gb microburst. So at a superficial level, it looks like you're seeing packet drops because of full buffers. Also, you're running the card in oversubscription mode. How much traffic is te4/7 pushing? I'd hazard a guess that you're running into over-subscription problems on the blade. I can't find the more detailed guide to the 6708 architecture on the cisco web site, but there's a brief overview here: > http://www.cisco.com/en/US/prod/collateral/switches/ps5718/ps708/prod_white_paper0900aecd80673385.html#wp9000681 while it's not going to give you exact details on tiny microbursts, I'd consider installing RTG or YRTG with a 30 second poll interval, and monitor all the ports on blade 4, along with the following aggregates. te4/1 + te4/2 te4/3 + te4/4 te4/5 + te4/6 te4/7 + te4/8 te4/1 + te4/2 + te4/3 + te4/4 te4/5 + te4/6 + te4/7 + te4/8 Do you have a second 6708 blade? You may need to consider running these ports in non-oversubscribed mode. Nick and speed is > unpredictably slowing. Servers are able to generate much more than > 10Gbps. I have tried to assign IP from this VLAN directly to > vlan-interface at 3750 and latence is bad as well. > > > The two problems which I can see at 7606 are following: > > 1) Input queue drops at the interface. They appear at the same time as > the high latence. I tried to set lower hold-queue, but no difference. > Any type of qos or other bandwidht limiting methods are applied. > > sitel-edge-new#show int te4/8 > TenGigabitEthernet4/8 is up, line protocol is up (connected) > Hardware is C7600 10Gb 802.3, address is 001e.f7f7.bd5f (bia > 001e.f7f7.bd5f) > Description: SITEL-TTC-New10GbE > MTU 1500 bytes, BW 10000000 Kbit, DLY 10 usec, > reliability 255/255, txload 3/255, rxload 126/255 > Encapsulation ARPA, loopback not set > Keepalive set (10 sec) > Full-duplex, 10Gb/s > Transport mode LAN (10GBASE-R, 10.3125Gb/s) > input flow-control is off, output flow-control is off > ARP type: ARPA, ARP Timeout 04:00:00 > Last input 00:00:07, output 00:00:41, output hang never > Last clearing of "show interface" counters 18:56:25 > Input queue: 0/4096/96151289/0 (size/max/drops/flushes); Total output > drops: 0 > Queueing strategy: fifo > Output queue: 0/4096 (size/max) > 30 second input rate 4942942000 bits/sec, 410813 packets/sec > 30 second output rate 143433000 bits/sec, 241176 packets/sec > 34434311308 packets input, 51018973201607 bytes, 0 no buffer > Received 21472 broadcasts (17607 multicasts) > 0 runts, 0 giants, 0 throttles > 0 input errors, 0 CRC, 0 frame, 96151289 overrun, 0 ignored > 0 watchdog, 0 multicast, 0 pause input > 0 input packets with dribble condition detected > 19623750753 packets output, 3094225873410 bytes, 0 underruns > 0 output errors, 0 collisions, 0 interface resets > 0 babbles, 0 late collision, 0 deferred > 0 lost carrier, 0 no carrier, 0 pause output > 0 output buffer failures, 0 output buffers swapped out > > > the second side of line looks ok > > TTC-3750-MAIN#show int te2/0/2 > TenGigabitEthernet2/0/2 is up, line protocol is up (connected) > Hardware is Ten Gigabit Ethernet, address is 001e.7a4f.fb9e (bia > 001e.7a4f.fb9e) > Description: TTC-SITEL-New10GbE > MTU 1600 bytes, BW 10000000 Kbit, DLY 10 usec, > reliability 255/255, txload 129/255, rxload 3/255 > Encapsulation ARPA, loopback not set > Keepalive not set > Full-duplex, 10Gb/s, link type is auto, media type is 10GBase-SR > Media-type configured as connector > input flow-control is off, output flow-control is unsupported > ARP type: ARPA, ARP Timeout 04:00:00 > Last input 00:00:51, output 00:00:16, output hang never > Last clearing of "show interface" counters 01:36:19 > Input queue: 0/4096/0/0 (size/max/drops/flushes); Total output drops: 0 > Queueing strategy: fifo > Output queue: 0/4096 (size/max) > 30 second input rate 149330000 bits/sec, 249506 packets/sec > 30 second output rate 5062720000 bits/sec, 420886 packets/sec > 1400794396 packets input, 104446053346 bytes, 0 no buffer > Received 0 broadcasts (1250 multicasts) > 0 runts, 0 giants, 0 throttles > 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored > 0 watchdog, 1250 multicast, 0 pause input > 0 input packets with dribble condition detected > 2427526833 packets output, 3649915537744 bytes, 0 underruns > 0 output errors, 0 collisions, 0 interface resets > 0 babbles, 0 late collision, 0 deferred > 0 lost carrier, 0 no carrier, 0 PAUSE output > 0 output buffer failures, 0 output buffers swapped out > > > > > 2) It looks that concerned transciever is a little bit overheated..but I > don't trust these sensors much.. > > sitel-edge-new#show interfaces transceiver > Transceiver monitoring is disabled for all interfaces. > > Optical Optical > Temperature Voltage Current Tx Power Rx Power > Port (Celsius) (Volts) (mA) (dBm) (dBm) > --------- ----------- ------- -------- -------- -------- > Te4/1 39.3 0.00 36.8 -2.8 -1.0 > Te4/2 34.6 0.00 43.1 -2.6 -3.3 > Te4/3 36.8 0.00 29.7 -2.5 -1.0 > Te4/4 35.3 0.00 5.9 -1.9 -1.7 > Te4/5 44.1 0.00 45.4 -2.0 -7.7 > Te4/6 40.0 0.00 36.0 -3.4 -2.2 > Te4/7 40.8 0.00 34.0 -3.3 -0.5 + > Te4/8 71.9 + 0.00 6.0 -3.2 -3.4 > > > > > some more debug info: > > 7606 -> > > sitel-edge-new#show platform hardware capacity fabric > Switch Fabric Resources > Bus utilization: current: 35%, peak was 47% at 19:53:03 CET Thu Mar 11 > 2010 > Fabric utilization: Ingress Egress > Module Chanl Speed rate peak rate peak > 1 0 20G 14% 21% @18:26 11Mar10 19% 31% @18:20 > 12Mar10 > 2 0 20G 25% 39% @17:50 11Mar10 2% 10% @02:07 > 12Mar10 > 2 1 20G 10% 26% @19:41 11Mar10 33% 49% @18:06 > 11Mar10 > 4 0 20G 25% 63% @13:00 14Mar10 5% 20% @18:15 > 11Mar10 > 4 1 20G 45% 79% @18:07 11Mar10 50% 73% @09:43 > 13Mar10 > 5 0 20G 2% 5% @14:22 12Mar10 12% 19% @19:08 > 11Mar10 > Switching mode: Module Switching > mode > 1 truncated > 2 truncated > 4 compact > 5 flow > through > > > > > I'm going to replace the "overheated" transciever in 7606 this night and > hope it's the solution..but don't trust it much. > > > Any advice would be really appreciated! > > > Best regards, > > > Jiri Prochazka > _______________________________________________ > cisco-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/cisco-nsp > archive at http://puck.nether.net/pipermail/cisco-nsp/ -- Network Ability Ltd. | Head of Operations | Tel: +353 1 6169698 3 Westland Square | INEX - Internet Neutral | Fax: +353 1 6041981 Dublin 2, Ireland | Exchange Association | Email: [email protected] _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/