Hi all,
I'm trying to put a 48-port 1G linecard in a C6500, and there's a
mismatch that I wonder if someone could explain to me.
The sup in the 6506 is a 720 PFC3B:
And the linecard I want to put in it uses a DFC3A. From the docs it
seems that this arrangement will work, but A) I have to reboot the box,
and B) PFC will fall back to operating as a PFC3A.
Also, I have two 10G line cards in this same box.
So my questions are:
What is the performance difference between the PFC3A and PFC3B?
Are there any gotchas with running the 10G linecards in this box in this
condition?
Thanks,
Tom
--
--------------------------------------------------------------------
Tom Ammon
Network Engineer
Office: 801.587.0976
Mobile: 801.674.9273
Center for High Performance Computing
University of Utah
http://www.chpc.utah.edu
_______________________________________________
cisco-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/