On 08/05/2010 07:52 PM, Youssef Bengelloun-Zahr wrote:
Hello Peter,

Have you read this :

http://www.cisco.com/en/US/products/hw/switches/ps708/products_configuration_example09186a008086ed2e.shtml

I have been through this situation several times and OIR really works... but
hey, you never what can happen out there ;-)

Maybe you should cut-off power from that particular module before removing
it but no garanties either.

IIRC you can't control power to sup slots.

We have (and do) remove and insert cards, includings sups, into 6500s without problem. The real issue is the potential for bus-stalls on insert, which requires careful alignment and forceful, no-hesitation insertion ;o)

I would advise the OP to just pull it.
_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to