Seen this - in our case it was the on-card power regulator that died. 6500 uses a single DC voltage (42V) in the backplane, and has voltage regulators on the cards. Regulator dies, and you lose the card.
You probably have a dead card. Time to call TAC/sub in spare/hunt down replacement. Brian Fitzgerald Sr. Network & Security Admin. ITS, Camosun College, Victoria, BC. On 10-11-25 6:57 AM, "Bayasgalan Bayantur" <[email protected]> wrote: > Hello Guys, Can anybody please help me to understand the below error is > related to Power/Chassis/Module ? %OIR-SP-6-PWRFAILURE: Module 3 is being > disabled due to power convertor failure %C6KPWR-SP-4-DISABLED: power to module > in slot 3 set off (FRU-power failed) 6513-SW2#hw-module module 3 > reset Proceed with reload of module?[confirm] % module 3 is operationally off > (FRU-power failed) 00:01:20: %C6KENV-SP-4-FANHIOUTPUT: Version 2 > high-output fan-tray is in effect 00:01:28: %OIR-SP-6-PWRFAILURE: Module 3 is > being disabled due to power convertor failure 00:01:28: %C6KPWR-SP-4-DISABLED: > power to module in slot 3 set off (FRU-power failed) -- > *********************** Таныг хүндэтгэсэн > Б.Баясгалан *********************** __________________________________________ > _____ cisco-nsp mailing list > [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp a > rchive at http://puck.nether.net/pipermail/cisco-nsp/ _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/