Howdy, We have a C6509 with 2xWS-SUP720
We have been having an issue where the secondary sup will just reload seemingly at random: 2011-03-23 08:49:06 Local7.Info xxxxx 212267: Mar 23 07:49:36.903 EST: %PFREDUN-SP-6-ACTIVE: Standby processor removed or reloaded, changing to Simplex mode There is no other log message about it.. 2011-03-23 08:49:06 Local7.Error xxxxx 212268: Mar 23 07:49:36.903 EST: %OIR-SP-3-PWRCYCLE: Card in module 6, is being power-cycled 'Module reset' After the card loaded I noticed these: Mar 10 15:15:11 EST: %CONST_DIAG-SP-3-HM_TEST_FAIL: Module 6 TestSPRPInbandPing consecutive failure count:10 Mar 10 15:15:11 EST: %CONST_DIAG-SP-6-HM_TEST_INFO: CPU util(5sec): SP=14% RP=6% Traffic=6% netint_thr_active[0], Tx_Rate[1233], Rx_Rate[881], dev=4[IPv6, fail=10] Mar 10 15:15:11 EST: %CONST_DIAG-SP-4-HM_TEST_WARNING: Sup switchover will occur after 10 consecutive failures Mar 10 15:16:44 EST: %CONST_DIAG-SP-3-HM_TEST_FAIL: Module 6 TestSPRPInbandPing consecutive failure count:15 Mar 10 15:16:44 EST: %CONST_DIAG-SP-6-HM_TEST_INFO: CPU util(5sec): SP=13% RP=22 % Traffic=5% netint_thr_active[0], Tx_Rate[872], Rx_Rate[640], dev=4[IPv6, fail=15] Mar 10 15:16:44 EST: %CONST_DIAG-SP-4-HM_TEST_WARNING: Sup switchover will occur after 10 consecutive failures Mar 10 15:18:16 EST: %CONST_DIAG-SP-3-HM_TEST_FAIL: Module 6 TestSPRPInbandPing consecutive failure count:20 Mar 10 15:18:16 EST: %CONST_DIAG-SP-6-HM_TEST_INFO: CPU util(5sec): SP=18% RP=1% Traffic=5% netint_thr_active[0], Tx_Rate[978], Rx_Rate[665], dev=4[IPv6, fail=20] Mar 10 15:18:16 EST: %CONST_DIAG-SP-4-HM_TEST_WARNING: Sup switchover will occur after 10 consecutive failures Mar 10 15:19:51 EST: %CONST_DIAG-SP-3-HM_TEST_FAIL: Module 6 TestSPRPInbandPing consecutive failure count:25 Mar 10 15:19:51 EST: %CONST_DIAG-SP-6-HM_TEST_INFO: CPU util(5sec): SP=18% RP=31% Traffic=5% netint_thr_active[0], Tx_Rate[889], Rx_Rate[677], dev=4[IPv6, fail=25] Mar 10 15:19:51 EST: %CONST_DIAG-SP-4-HM_TEST_WARNING: Sup switchover will occur after 10 consecutive failures Mar 10 15:21:28 EST: %CONST_DIAG-SP-3-HM_TEST_FAIL: Module 6 TestSPRPInbandPing consecutive failure count:30 Mar 10 15:21:28 EST: %CONST_DIAG-SP-6-HM_TEST_INFO: CPU util(5sec): SP=19% RP=4% Traffic=5% netint_thr_active[0], Tx_Rate[861], Rx_Rate[502], dev=4[IPv6, fail=30] Mar 10 15:21:28 EST: %CONST_DIAG-SP-4-HM_TEST_WARNING: Sup switchover will occur after 10 consecutive failures Mar 10 15:23:05 EST: %CONST_DIAG-SP-3-HM_TEST_FAIL: Module 6 TestSPRPInbandPing consecutive failure count:35 Mar 10 15:23:05 EST: %CONST_DIAG-SP-6-HM_TEST_INFO: CPU util(5sec): SP=12% RP=1% Traffic=5% netint_thr_active[0], Tx_Rate[1058], Rx_Rate[598], dev=4[IPv6, fail=35] Mar 10 15:23:05 EST: %CONST_DIAG-SP-4-HM_TEST_WARNING: Sup switchover will occur after 10 consecutive failures Mar 10 15:24:37 EST: %CONST_DIAG-SP-3-HM_TEST_FAIL: Module 6 TestSPRPInbandPing consecutive failure count:40 Mar 10 15:24:37 EST: %CONST_DIAG-SP-6-HM_TEST_INFO: CPU util(5sec): SP=13% RP=1% Traffic=5% netint_thr_active[0], Tx_Rate[1165], Rx_Rate[705], dev=4[IPv6, fail=40] Mar 10 15:24:37 EST: %CONST_DIAG-SP-4-HM_TEST_WARNING: Sup switchover will occur after 10 consecutive failures Mar 10 15:26:12 EST: %CONST_DIAG-SP-3-HM_TEST_FAIL: Module 6 TestSPRPInbandPing consecutive failure count:45 Mar 10 15:26:12 EST: %CONST_DIAG-SP-6-HM_TEST_INFO: CPU util(5sec): SP=38% RP=2% Traffic=5% netint_thr_active[0], Tx_Rate[1132], Rx_Rate[708], dev=4[IPv6, fail=45] Mar 10 15:26:12 EST: %CONST_DIAG-SP-4-HM_TEST_WARNING: Sup switchover will occur after 10 consecutive failures This is SXI3, any bugs anyone is aware of? thanks, -Drew _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/