dug through some kit -- found sfp-ge-s and a 62.5um cable.
same interfaces being used.

link came up for me. again -- this is with n5000, not n5500, but i wouldn't think too great of a difference?

===============================
asr1002-1(config)#do sh run int gig 0/0/3
Building configuration...

Current configuration : 74 bytes
!
interface GigabitEthernet0/0/3
 no ip address
 no negotiation auto
end

asr1002-1(config)#do sh int gig 0/0/3
GigabitEthernet0/0/3 is up, line protocol is up
  Hardware is 4XGE-BUILT-IN, address is 588d.09ef.5103 (bia 588d.09ef.5103)
  MTU 1500 bytes, BW 1000000 Kbit/sec, DLY 10 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation ARPA, loopback not set
  Keepalive not supported
  Full Duplex, 1000Mbps, link type is force-up, media type is SX
  output flow-control is on, input flow-control is on
  ARP type: ARPA, ARP Timeout 04:00:00
  Last input 00:00:01, output never, output hang never
  Last clearing of "show interface" counters never
  Input queue: 0/375/0/0 (size/max/drops/flushes); Total output drops: 0
  Queueing strategy: fifo
  Output queue: 0/40 (size/max)
  5 minute input rate 0 bits/sec, 0 packets/sec
  5 minute output rate 0 bits/sec, 0 packets/sec
     36 packets input, 4800 bytes, 0 no buffer
     Received 0 broadcasts (0 IP multicasts)
     0 runts, 0 giants, 0 throttles
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
     0 watchdog, 36 multicast, 0 pause input
     0 packets output, 0 bytes, 0 underruns
     0 output errors, 0 collisions, 5 interface resets
     0 unknown protocol drops
     0 babbles, 0 late collision, 0 deferred
     0 lost carrier, 0 no carrier, 0 pause output
     0 output buffer failures, 0 output buffers swapped out

---------------------------------

n5020-1# sh run int e1/1

!Command: show running-config interface Ethernet1/1
!Time: Fri Apr 15 21:16:15 2011

version 4.2(1)N2(1)

interface Ethernet1/1
  speed 1000

n5020-1# sh int e 1/1
Ethernet1/1 is up
Hardware: 1000/10000 Ethernet, address: 0005.73a1.6508 (bia 0005.73a1.6508)
  MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation ARPA
  Port mode is access
  full-duplex, 1000 Mb/s, media type is 1/10g
  Beacon is turned off
  Input flow-control is off, output flow-control is off
  Rate mode is dedicated
  Switchport monitor is off
  Last link flapped 00:03:47
  Last clearing of "show interface" counters 00:33:26
  30 seconds input rate 0 bits/sec, 0 packets/sec
  30 seconds output rate 184 bits/sec, 0 packets/sec
  Load-Interval #2: 5 minute (300 seconds)
    input rate 0 bps, 0 pps; output rate 96 bps, 0 pps
  RX
    0 unicast packets  1 multicast packets  0 broadcast packets
    1 input packets  81 bytes
    0 jumbo packets  0 storm suppression packets
    0 runts  0 giants  0 CRC  0 no buffer
    0 input error  0 short frame  0 overrun   0 underrun  0 ignored
    0 watchdog  0 bad etype drop  0 bad proto drop  0 if down drop
    0 input with dribble  0 input discard
    0 Rx pause
  TX
    0 unicast packets  218 multicast packets  0 broadcast packets
    218 output packets  32576 bytes
    0 jumbo packets
    0 output errors  0 collision  0 deferred  0 late collision
    0 lost carrier  0 no carrier  0 babble
    0 Tx pause
  2 interface resets
===============================

i've used this article in the past[0]. while dated -- it seems to have some good information. it doesn't appear that speed nonegotiate is accepted under the 4.2 code on n7k -- so i'd assume similar parity in 4.2 on n5k platform.

i tried to pull of the optic information from my n5k -- but its not coming out clean. however, when i use this transceiver in n7k, i get the following output

================================
n7k-1# sh int e 1/25 trans
Ethernet1/25
    transceiver is present
    type is 1000base-SX
    name is CISCO-FINISAR
    part number is FTLF8519P2BNL-C6
    revision is B
    serial number is FNS143907J7
    nominal bitrate is 1300 MBit/sec
    cisco id is --
    cisco extended id number is 4
==================================

when i try to configure speed on n7k running 5.1(3) code, i get the following options (which may lend more insight into why this works

===================================
n7k-1(config)# int e 1/25
n7k-1(config-if)# speed ?
  10     10Mb/s
  100    100Mb/s
  1000   1Gb/s
  10000  10Gb/s
  auto   Auto negotiate speed
====================================

not sure if hard-setting the speed and negotiation are mutually exclusive -- but i'm just passing along what i'm seeing.

q.

[0]http://www.netcraftsmen.net/component/content/article/69-data-center/807-migrating-to-nexus-7000-from-catalyst-6500-and-4500-switches.html

==
()  ascii ribbon campaign - against html e-mail
/\  www.asciiribbon.org   - against proprietary attachments

On 04/15/2011 02:01 PM, Gert Doering wrote:
Hi,

On Fri, Apr 15, 2011 at 01:44:03PM -0700, quinn snyder wrote:
testing in my lab now -- simple back to back copper over glc-t between
n5020 running 4.2(1)n2(1) and asr1002 running 3.1.0s

Thanks for testing, but I'm afraid this won't bring new information -
copper GE and fiber GE is significantly different here, and as far as
I understand, there is no way to run GE copper without negotiation
(both ends need to agree who is PHY master and slave, and sort out the
wire pairs).

So it might disable negotiation of flow control and such, and might
show the link as "always up", but the PHY will still negotiate.

[..]
interface Ethernet1/1
   speed 1000

We (the customer) had that, but that wasn't sufficient.  But if that
indeed disables link negotiation for fiber SFPs, we had some other
problem...

In any case: thanks for the suggestions so far!

gert

_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to