On 18/04/2011 14:38, Righa Shake wrote:
Am receiving the following error on my logs.
However am unable to to get to know what it is and clear it.

%SONET-4-ALARM: SIP0/0:  POS0/0/0: B3 BER exceeds threshold, TC alert
declared.

TC means "threshold-crossing". The alarm means that the bit error rate (BER) on the link has exceeded a predefined threshold. Probably you have a physical error on the link and you need to get your telco to check it out.

For more details, see:

http://www.cisco.com/en/US/tech/tk482/tk607/technologies_tech_note09186a0080094a79.shtml

Nick