On the 6500 you can only do POS so if they want something else it isn't going 
to work.
If you are using the POS interface as an xconnect end-point it should do what 
you want.
TDM does not work over most MPLS without significant buffering in any case.

Mack

From: Tim Jackson [mailto:[email protected]]
Sent: Tuesday, May 24, 2011 10:44 AM
To: FF
Cc: Mack McBride; [email protected]
Subject: Re: [c-nsp] OC-48 transport over Cisco 6500

They'll notice..

Assuming they're doing TDM or something besides PoS over it, it won't look the 
same at all.. The PoS interfaces are STS-48c only..

Maybe if they're doing just PoS it might work, but who uses PoS on OC-48 
anymore? Cheaper to do 10G...

--
Tim
On Tue, May 24, 2011 at 11:38 AM, FF 
<[email protected]<mailto:[email protected]>> wrote:
Thanks for responding. I'm looking at something like this:
http://www.cisco.com/en/US/prod/collateral/modules/ps2831/ps4370/product_data_sheet09186a0080092241.html

Will someone connecting to this for OC-48 transport between two
locations with MPLS encapsulation (xconnect) notice anything different
via a normal mux port? I think what you're saying is, "no". :)

On Tue, May 24, 2011 at 11:59 AM, Mack McBride 
<[email protected]<mailto:[email protected]>> wrote:
> The POS looks like a standard 6500 layer 3 port with of course the added POS 
> commands.
> This means standard MPLS commands should work.
> The older POS cards lack some of the functionality of the newer cards.
> Someone may have more information if you provide the exact line card.
>
> Mack McBride
> Network Architect
>
> -----Original Message-----
> From: 
> [email protected]<mailto:[email protected]> 
> [mailto:[email protected]<mailto:[email protected]>]
>  On Behalf Of FF
> Sent: Monday, May 23, 2011 9:25 PM
> To: [email protected]<mailto:[email protected]>
> Subject: [c-nsp] OC-48 transport over Cisco 6500
>
> If I'm trying to transport OC-48 between two customer locations via
> MPLS on a Cisco 6500...
>
> Would simple MPLS/xconnect work using the appropriate OC-48-OSM on
> each side? [i.e., will the OC-48-OSM look like a traditional SONET
> interface such as one would see from a 15454 or similar mux to the
> customer equipment?]
>
> thanks in advance,
>
> --
>
> FF
> _______________________________________________
> cisco-nsp mailing list  
> [email protected]<mailto:[email protected]>
> https://puck.nether.net/mailman/listinfo/cisco-nsp
> archive at http://puck.nether.net/pipermail/cisco-nsp/
>


--
FF

_______________________________________________
cisco-nsp mailing list  
[email protected]<mailto:[email protected]>
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to