That was it.  Thanks.

Josh

On Tue, Jul 5, 2011 at 4:23 PM, Justin M. Streiner
<[email protected]>wrote:

> On Tue, 5 Jul 2011, Josh Baird wrote:
>
>  the interface name for a 7206 would be "serial <slot>/0:0," however this
>> does not appear to be a valid interface on my 7206.  Does anyone know how
>> I
>> can figure out what the interface name really is for the PA?  Or, maybe
>> someone who has experience with this PA can tell me?
>>
>
> What you're seeing are the entities for the T1 controller ports.  You need
> to go into the T1 controller and define the number of timeslots, framing,
> coding, clock source, etc.  Once you do that, there will be a serial
> interface that you can configure with encapsulation, IP address, etc...
>
> jms
>