In some simple testing I did awhile back on the 5K the frame was dropped, not sure about the 7K however. The only oddity I had with regards to frames being accepted which probably shouldn't was on a port-channel member port in active mode (LACP) which was physical up but LACP was not active on (no neighbor), but I believe there is now a command to rectify that behavior.
Phil On 7/15/11 1:32 PM, "Brandon Applegate" <[email protected]> wrote: >I plan on digging around some on my own, but wanted to quickly see if >anyone has any data, or lab experience etc on this. > >My question is that if I am connected to an access port, and I send a >tagged frame, will this frame make it to the VLAN in question ? > >Thanks. > >-- >Brandon Applegate - CCIE 10273 >PGP Key fingerprint: >7407 DC86 AA7B A57F 62D1 A715 3C63 66A1 181E 6996 >"SH1-0151. This is the serial number, of our orbital gun." > >_______________________________________________ >cisco-nsp mailing list [email protected] >https://puck.nether.net/mailman/listinfo/cisco-nsp >archive at http://puck.nether.net/pipermail/cisco-nsp/ _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/