add command 'channel-group 5 mode on' to interface. This creates port-channel interface
configuration below from one 7609 SUP720

interface Port-channel5
 description xxx link
 switchport
 switchport trunk encapsulation dot1q
switchport trunk allowed vlan 1-253,255-283,285-288,291-306,308-337,339-355
 switchport trunk allowed vlan add 357-372,375,376,380-382,384-388,390-531
 switchport trunk allowed vlan add 534-603,607-610,612-691,693-703,705-899
 switchport trunk allowed vlan add 901-973,975-1156,1158-1207,1209-1252
 switchport trunk allowed vlan add 1254-1268,1270,1271,1274-1276,1278-1296
 switchport trunk allowed vlan add 1298-1356,1358-1383,1385-1422,1424-1513
 switchport trunk allowed vlan add 1515-1524,1526-1604,1606,1608-1628,1630
 switchport trunk allowed vlan add 1632-1968,1971-1979,1981-2099,2101-2204
switchport trunk allowed vlan add 2206-2899,2901-3472,3474,3476-3478,3480-4094
 switchport mode trunk
 switchport nonegotiate
 mtu 2200
 load-interval 30
 mls qos trust cos

interface TenGigabitEthernet7/1
 description xxx portchannel 5
 switchport
 switchport trunk encapsulation dot1q
switchport trunk allowed vlan 1-253,255-283,285-288,291-306,308-337,339-355
 switchport trunk allowed vlan add 357-372,375,376,380-382,384-388,390-531
 switchport trunk allowed vlan add 534-603,607-610,612-691,693-703,705-899
 switchport trunk allowed vlan add 901-973,975-1156,1158-1207,1209-1252
 switchport trunk allowed vlan add 1254-1268,1270,1271,1274-1276,1278-1296
 switchport trunk allowed vlan add 1298-1356,1358-1383,1385-1422,1424-1513
 switchport trunk allowed vlan add 1515-1524,1526-1604,1606,1608-1628,1630
 switchport trunk allowed vlan add 1632-1968,1971-1979,1981-2099,2101-2204
switchport trunk allowed vlan add 2206-2899,2901-3472,3474,3476-3478,3480-4094
 switchport mode trunk
 switchport nonegotiate
 mtu 2200
 load-interval 30
 mls qos trust cos
 channel-group 5 mode on


interface TenGigabitEthernet7/3
 description xxx portchannel 5
 switchport
 switchport trunk encapsulation dot1q
switchport trunk allowed vlan 1-253,255-283,285-288,291-306,308-337,339-355
 switchport trunk allowed vlan add 357-372,375,376,380-382,384-388,390-531
 switchport trunk allowed vlan add 534-603,607-610,612-691,693-703,705-899
 switchport trunk allowed vlan add 901-973,975-1156,1158-1207,1209-1252
 switchport trunk allowed vlan add 1254-1268,1270,1271,1274-1276,1278-1296
 switchport trunk allowed vlan add 1298-1356,1358-1383,1385-1422,1424-1513
 switchport trunk allowed vlan add 1515-1524,1526-1604,1606,1608-1628,1630
 switchport trunk allowed vlan add 1632-1968,1971-1979,1981-2099,2101-2204
switchport trunk allowed vlan add 2206-2899,2901-3472,3474,3476-3478,3480-4094
 switchport mode trunk
 switchport nonegotiate
 mtu 2200
 load-interval 30
 mls qos trust cos
 channel-group 5 mode on



site#sh etherchannel 5 detail
Group state = L2
Ports: 2   Maxports = 8
Port-channels: 1 Max Port-channels = 1
Protocol:    -
Minimum Links: 0
                Ports in the group:
                -------------------
Port: Te7/1
------------

Port state    = Up Mstr In-Bndl
Channel group = 5           Mode = On               Gcchange = -
Port-channel = Po5 GC = - Pseudo port-channel = Po5
Port index    = 0           Load = 0x55             Protocol =    -
Mode = LACP

Age of the port in the current state: 160d:04h:22m:01s

Port: Te7/3
------------

Port state    = Up Mstr In-Bndl
Channel group = 5           Mode = On               Gcchange = -
Port-channel = Po5 GC = - Pseudo port-channel = Po5
Port index    = 1           Load = 0xAA             Protocol =    -
Mode = LACP

Age of the port in the current state: 117d:23h:20m:43s

                Port-channels in the group:
                ----------------------

Port-channel: Po5
------------

Age of the Port-channel   = 167d:04h:04m:53s
Logical slot/port   = 14/5          Number of ports = 2
GC                  = 0x00000000      HotStandBy port = null
Port state          = Port-channel Ag-Inuse
Protocol            =    -
Fast-switchover     = disabled
Direct Load Swap    = disabled

Ports in the Port-channel:

Index   Load    Port      EC state        No of bits
------+------+--------+------------------+-----------
  0     55     Te7/1      On                 4
  1     AA     Te7/3      On                 4

Time since last port bundled:    117d:23h:20m:48s    Te7/3
Time since last port Un-bundled: 120d:20h:49m:00s    Te7/3

Last applied Hash Distribution Algorithm: Fixed
Channel-group Iedge Counts:
--------------------------:
Access ref count       : 0
Iedge session count    : 0

Den 8/28/2011 7:29 AM, skrev Olivier CALVANO:
Hi

I request a small help:

We have two cisco 6500 with SUP720-3B and 4 port 10G card.

First C6500 are not on the same site of the second and we have two fiber
for the interconnect.

Actually, only one fiber is used, we want connect the second for create a
etherchannle (2x10GB) and for secure (don't lost the connection if one of
the fiber
are cut).

I am search a very basic config sample for this, the cisco are used only in
switch with
vlan.

Thanks for your help
Olivier
_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to