Folks, I've been having about 1 T1 per month go down on a specific slot in a 7206 VXR. It's slot 4. I have replaced the PA-MC-T3 that is in there, but I still keep getting individual T1 circuits go down. Each time, it's a different channel on the DS3 card that is "down".
We have opened tickets with the telco and say everything looks clean on the DS3, but when a T1 is down, they can't loop up that individual channel on the DS3 card. We have been assuming the card was bad so we've just replaced it a couple of times, BUT today we just pulled the existing one out and reseated it. The down T1 came back up and runs clean now.... I know this is old equipment, but anyone have similar issues? The cards are cheap enough that we can replace them, but having to do that every month or two seems really odd. Especially now that just reseating the DS3 card seems to have worked. I'm worried there might be something more sinister going on. Thanks in advance, -Nick Voth _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/