John, thank you for this bug ID! In case I'll have an opportunity to test those Avago AFCT-5611Z GBIC's further, I'll let you all know about the results.
regards, martin 2011/10/4 John Kougoulos <[email protected]>: > > > On Tue, 4 Oct 2011, Martin T wrote: > >> WS-C2960G-24TC-L[Gi0/22] <-> [Gi3/4]WS-C4506 >> >> SFP in WS-C2960G-24TC-L is a noname 1000BASE-LX10 transceiver working >> thanks to "service unsupported-transceiver". GBIC in WS-C4506 is an >> Avago AFCT-5611Z 1000BASE-LX10. Linecard model in WS-C4506 is >> WS-X4306-GB. >> >> I had a situation where WS-C2960G-24TC-L reloaded, but link between >> WS-C2960G-24TC-L and WS-C4506 did not came up until I did "shutdown" >> and "no shutdown" to port Gi3/4 in WS-C4506. I have seen similar >> behaviour with GBIC transceivers on WS-X4306 linecard as well(in >> another WS-C4506) and for example in case there is a fibre cut between >> the switches, once the cable is repaired, sometimes one needs to make >> "shutdown" and "no shutdow" to GBIC port in order for line protocol to >> come up. >> > > Martin, > > check this bugid: CSCsq54639 > > Regards, > John > _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/