On 7 Nov 2011, at 17:00, [email protected] wrote: > That sounds like an IOS bug. > > What does "sh idprom int Tex/y | inc endor" say for one of the non-Cisco > parts, compared to a Cisco part?
Mystery solved: without going into the full long story, 75oC ambient temperature in a datacentre causing a config register to become corrupt ended in an ancient backup IOS being booted into, one without DOM support. Prior to the reboot, the only third-party Xenpaks were SR and so had no DOM support anyway (and I won't even go into the confusion caused by the output of idprom claiming our real Cisco SR xenpaks are of the + variety, i.e. DOM supporting). > ... > We've never had problems with such transceivers and DOM, including with > SFP+ in a X2->SFP+ converter in a 6716. Well that in itself is useful to know - thanks. Michael. _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/