On 2012-03-02 09:13, Artyom Viklenko wrote:

I'm tring to clarify my understanding of switching paths on these
line cards. From one point of view, Cisco docs says that if the
traffic should ingress via one port on the line card and then
should egress through another port on the same line card it will
never leave this line card. So it will be switched via internal
bus. Right?

No, and if it says so somewhere, please point it to the doc team
to fix it.

Both 6704 and 6708 have two complex of Fabric ASICs.
The 6708 you can see on figure 21 here:
http://www.cisco.com/en/US/prod/collateral/switches/ps5718/ps708/prod_white_paper0900aecd80673385.html

The port mappings for Fabric ASICs should be found in the hardware
installation notes under the 'Switch fabric connections' in the
tables for specific LC:
http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Module_Installation/Mod_Install_Guide/02ethern.html#wp1048010

Essentially, traffic from one Fabric ASIC to the ports on the
other Fabric ASIC will go over the fabric itself. Only traffic
belonging the the same Fabric ASIC will be switched locally if of
course there's a DFC installed.

--
"There's no sense in being precise when |               Łukasz Bromirski
 you don't know what you're talking     |      jid:[email protected]
 about."               John von Neumann |    http://lukasz.bromirski.net