Hi, > We'll have to consider if we try to find new PSUs (we have some 6000W in > some remote boxes that could cope with 3000W) or move the module. We > prefer to use slot 8 for aesthetic reasons but nobody really looks that > these boxes that much.
choosing a slot due to aesthetic reasons is not the best of ideas - you are aware that on the 6500 chassis certain slots are poorer than others? we just put our module into the slot that the reserved power was on - as we run with just 1 supervisor (we have other resilience/redundancy methods that dont rely on the 2nd sup hackiness) alan _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/