Not according to AT&T. They say they provide a path, and clocking is up to us - that's why one side uses internal, and the other is set to line. That normally works fine, and has worked on these circuits until recently.
And again, I am seeing the same problems on the standalone T1s and the T3 channels. Sincerely, Michael Malitsky > -----Original Message----- > From: Andrew Miehs [mailto:[email protected]] > Sent: Thursday, August 30, 2012 6:29 PM > To: Michael Malitsky > Cc: N. Max Pierson; [email protected] > Subject: Re: [c-nsp] 7200 Line protocol bouncing > > Sent from a mobile device > > On 31/08/2012, at 9:07, "Michael Malitsky" <[email protected]> wrote: > > > > > The single T1s are configured to use internal clock. (remote are set > to > > recover clock from line). > > > > Normally the carrier provides the clock on the line - and you should > just sync to it... _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/