I am running
Switch#show license
Index 1 Feature: AdvancedMetroIPAccess
Period left: Life time
License Type: Permanent
License State: Active, In Use
License Count: Non-Counted
License Priority: Medium
Index 2 Feature: MetroIPAccess
Index 3 Feature: 10GEUpgrade
Period left: Life time
License Type: Permanent
License State: Active, In Use
License Count: Non-Counted
License Priority: Medium
What do you get after putting in a name for the connect - all I get is
Dialer as an option.
Switch(config)#connect FOO ?
Dialer Dialer interface
On 28/Sep/2012 12:22 a.m., Andrew K. wrote:
Are you running the advanced services license?
me360x-universalk9-mz.152-2.S1.bin
switch#sh license
Index 1 Feature: AdvancedMetroIPAccess
Period left: Life time
switch(config)#connect ?
WORD Name for this connection
On 9/27/2012 6:38 AM, Nick Hilliard wrote:
On 27/09/2012 03:38, Ivan wrote:
Just connecting 2 service instances is all I would like to do.
There is a difference between an ESI and an xconnect. In the case of an
ESI, the switch will learn all the mac addresses passing over the link.
This doesn't happen for an xconnect.
If you're dealing with a small number of mac addresses, this probably
isn't
a problem. If you're dealing with a lot, then it may be...
Nick
_______________________________________________
cisco-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/
_______________________________________________
cisco-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/