On 25 January 2013 09:58, Pshem Kowalczyk <[email protected]> wrote:
> Hi,
>
> This setup works if I strip both tags on ingress. The downside is that
> if do that I lose the CoS bits. Is there a way of preserving the inner
> VLAN tag with an EVC and bridge domain?

Replying to my own email.
The way to achieve this is to match only on the outer tag and strip it
on both EVCs. This way the inner tag passed through the bridge domain
unchanged.

kind regards
Pshem